Setup
3. Connect the gun fluid supply hose (G) to the fluid
inlet fitting (15) or the fluid swivel connector (22).
See F
. 6.
IG
NOTE: Purchase a fluid swivel connector (22)
separately with Kit 189018.
15
22
F
. 6: Connect the gun fluid supply hose
IG
4. Connect the other end of the gun fluid supply hose
(G) to the pump fluid outlet.
12
Flush Before Using
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid
contaminating your fluid with oil, flush the equipment
with a compatible solvent before using the equipment.
See Flushing Procedure, page 21.
Follow the Pressure Relief Procedure, page 15.
G
G
3A8099A