Parameter Menus
Laser On Time
Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan
attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds.
To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes
beginning on
page 9-134
that correspond to the desired on time. Times less than 1.0
second must have a leading zero. For example, to set an on time of 0.5 seconds, scan the
bar code below, then scan the "0" and "5" bar codes. If you make an error, or wish to change
your selection, scan the
Cancel
bar code on
page
9-136.
Laser On Time
9-13