Se 3223 Scanning Specifications; Se 3223 Slab/Raster Decode Zone - Symbol SE 2223 Integration Manual

Scan engine
Table of Contents

Advertisement

SE 2223/3223 Scan Engine Integration Guide

SE 3223 Scanning Specifications

SE 3223 Slab/Raster Decode Zone

Note: Typical performance at 68˚F (20˚C) on high quality symbols
in normal room light.
Vcc = 5V
Front of
Chassis
6.6 mil PDF417
2.0
10 mil PDF417
4.5
7.5
0
5
In.
cm
0
12.7
Figure 5-1. SE 3223 Slab/Raster Decode Zone
The decode zone is a function of various symbol characteristics including density, print
contrast, wide to narrow ratio and edge acuity. Scanner is in horizontal orientation.
5-4
6.25
10.5
15 mil PDF417
15.0
55 mil 1D
10
15
20
25.4
38.1
50.8
Depth of Field
33.0
25
30
35
25.4
63.5
88.9
In.
cm
W
10 25.4
i
d
7.5
15.2
t
5
10.1
h
2.5
5.1
o
0
0
f
2.5
5.1
F
5
10.1
i
e
7.5
15.2
l
25.4
10
d

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se 3223

Table of Contents