Beeper Frequency Adjustment; Laser On Time - Symbol SE955 Integration Manual

Table of Contents

Advertisement

8-10
SE955 Integration Guide

Beeper Frequency Adjustment

Parameter # 0xF0 0x91
This parameter adjusts the frequency of the high beeper tone from the nominal 2500 Hz to another frequency matching the resonances
of the installation. It is programmable in
10 Hz increments from 1220 Hz to 3770 Hz.
To increase the frequency, scan the bar code below, then scan three numeric bar codes beginning on
the desired frequency adjustment divided by 10. For example, to set the frequency to 3000 Hz (an increase of 500 Hz), scan numeric
bar codes 0, 5, 0, corresponding to 50, or (500/10).
To decrease the frequency, scan the bar code below, then scan three numeric bar codes beginning on
the value (256 - desired adjustment/10). For example, to set the frequency to 2000 Hz (a decrease of 500 Hz), scan numeric bar codes
2, 0, 6, corresponding to 206, or (256 - 500/10).
To change the selection or cancel an incorrect entry, scan the

Laser On Time

Parameter # 0x88
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second
increments from 0.50 to 25.5 seconds.
To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on
desired on time. Single digit numbers must have a leading zero. For example, to set an on time of 0.5 seconds, scan the bar code
below, then scan the "0", "5" and "0" bar codes; to set an on time of 10.5 seconds, scan the bar code below, then scan the "1", "0"
and "5" bar codes. To change the selection or cancel an incorrect entry, scan
Cancel
bar code on
Beeper Frequency Adjustment
(Default: 2500 Hz)
Cancel
Laser On Time
(Default: 3.0 sec.)
page 8-73
that correspond to
page 8-73
that correspond to
page
8-74.
page 8-73
that correspond to the
on
page
8-74.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se-955