System Log

Important events are recorded in the System Log. The source of the event with the date
and time at which the event occurred is recorded along with an indication of its severity:
·
Error
·
Notice
·
Warning
·
Information
With the default logging level configuration, only events with severity level of "Notice" and
"Error" are recorded in the System Log. The logging level can be configured separately for
each software function.
For more information see the User Interface Handbook 667/HU/46000/000.
3.13

Site Log

The Site Log records significant site events. System firmware update is automatically
recorded in the site log. It is also possible for the user to create text records, either with or
without a file attachment.
Attachments can be useful to record site details through diagrams, photographs,
documents, etc.
For more information see the User Interface Handbook 667/HU/46000/000.
3.14

Remote Reboot

Remote reboot allows the Stratos Outstation to be rebooted. This function is available on
the System web page.
3.15

Inventory Information

Where available, inventory information is collected about the various assets within the
system (software and hardware). This information is available from the web page:
Status and Configuration – System – Status – Inventory – Devices
For more information see the User Interface Handbook 667/HU/46000/000.
The following boards contain inventory information:
Data
Part Number
Hardware Issue
Serial Number
Date
Manufacture
Description
Software
Security classification
Unrestricted
Version
3
Last Editor
Alan Doyle
Document Name
Stratos Outstation General and ICM Handbook
Copyright © Siemens plc 2014. All Rights Reserved.
CPU
PSU
48-16
IO
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
of
ü
ü
ü
part ü
ü
ü
Mobility and Logistics is a division of Siemens Plc
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
TC12
IDB
Adaptor
û
û
û
û
û
û
û
û
û
û
û
ü
Page
19 of 92
Status
Issued
Date
05-Oct-2017
Document No.
667/HB/52250/000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents