Self Test - Siemens Stratos Outstation General, Installation, Commissioning & Maintenance Handbook

Hide thumbs Also See for Stratos Outstation:
Table of Contents

Advertisement

6 S
T
ELF
EST
The Stratos Outstation self test functions are present to aid fault finding and are accessed
through the Tester web page on the top navigation pane. Results for tests are displayed
against each test with totals available at the top of the web page for ease of analysis.
To be able to run test scenarios the Tester application must first be run from
the System web page by clicking on the Run button alongside TesterApp.
Tests are split into test scenarios which are selected from the drop-down menu at the top
of the page. The following scenarios are available:
· Stratos Outstation System Test
· Stratos Outstation CPU PCB Test
· Stratos Outstation USB Test
· Stratos Outstation Modem Port (PL8) Test
· Stratos Outstation Aux Port (PL2) Test
· All Tests
When test(s) are run a test progress bar is displayed below the totals data. If any test fails
the bar is displayed in Red, otherwise it will be displayed in Green.
For each test scenario, the set of tests is displayed in the table and the user has the
option to run tests individually or as a set. Tests can be run once or continuously by
selecting the Loop tickbox. A log is available for each test which shows in more detail the
test functions and pass/fail state for the last run.
Note. Some test need specific connections or loopback adaptors to pass and therefore
may report test failures if these are not available.
The system test scenario should be used as part of the on-site testing and validation
process. Table 29 shows the tests included in the system test scenario.
LED
Mass Storage
Licence Reader
Licence Card
Licence Inventory
System Version
RTC
Security classification
Unrestricted
Version
3
Last Editor
Alan Doyle
Document Name
Stratos Outstation General and ICM Handbook
Copyright © Siemens plc 2014. All Rights Reserved.
Description
Checks for a mass storage device and whether
it can be accessed
Checks the on board licence card reader
Checks the licence card in the on board reader
Reads and logs the installed licences
Checks that the system version data can be
accessed
Checks that the RTC hardware operates
correctly
Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Page
Status
Date
Document No.
Mobility and Logistics is a division of Siemens Plc
Expected
result during
normal
installation
Pass
Pass
Pass
Pass
Pass
Pass
71 of 92
Issued
05-Oct-2017
667/HB/52250/000

Hide quick links: