1) With reference to EN 61121. 7 kg of cotton and a spin speed at 1000 rpm.
2) Energy consumption per year in kWh, based on 160 drying cycles of the standard cotton programme at full
and partial load, and the consumption of the low-power modes. Actual energy consumption per cycle will
depend on how the appliance is used (REGULATION (EU) No 392/2012).

Machine settings

Setting
BUZZER permanent off
Water hardness
Water contains, a variable
quantity of limestone and miner-
al salts of which quantities vary
according to geographical loca-
tions thus varying its conductivi-
ty values.
Relevant variations of the con-
ductivity of the water compared
to those prefixed by the factory
could slightly influence the re-
sidual humidity of the laundry at
the end of the cycle. Your dryer
allows you to regulate the sen-
sitivity of the drying sensor
based on conductivity values of
the water.

Hints for test institutes

Parameters possible to checked by the Test In-
stitutes:
• Energy consumption (corrected with final hu-
midity) during the cupboard dry cotton cycle
with nominal load.
• Energy consumption (corrected with final hu-
midity) during the cupboard dry cotton cycle
with half load.
• Final humidity (during cupboard dry cotton,
iron dry cotton and cupboard dry easy care)
28
Off-mode
1. Turn the programme selector to any programme.
2. Press simultaneously the INTENSIVE and LONG ANTICREASE
buttons and hold down for approx. 5 seconds.
3. The buzzer is by default always off.
1. Turn the programme selector to any programme.
2. Press simultaneously the LONG ANTICREASE and START/
PAUSE buttons and hold down for approx. 5 seconds. The current
setting is on the display:
low conductivity <300 micro S/cm
medium conductivity 300-600 micro S/cm
high conductivity >600 micro S/cm
3. Press the START/PAUSE button sequentially until you set desired
level.
4. To memorize setting press simultaneously the the LONG ANTI-
CREASE and START/PAUSE buttons or turn knob to O off position
• Condensation efficiency (corrected with final
All the cycles have to be checked in accord-
ance with EN 61121 (Tumble dryers for house-
hold use – Methods for measuring the perform-
ance).
0,68
Implementation
humidity) during cupboard dry cotton cycle
with nominal and half load
www.zanussi.com