Ratings and Specifications
Model
Technical
Detection method
Frequency band
Transmitter outputs
Interlock type (ISO 14119)
Coded level (ISO 14119)
Actuator
Response time (ON to OFF)
Risk time
Startup time
Typical operating distance
(Sn)
(IEC 60947-5-3)
Assured operating distance
(Sao)
(IEC 60947-5-3)
Assured switch-off distance
(Sar)
Differential travel
Repeat accuracy (R)
Electrical
Supply voltage (Ue)
Current consumption (Io)
Overvoltage category
Pollution degree
Conditional short-circuit current
External device fuse rating
Accepted test pulse duration
on input signal
Safety input
Test pulse interval
Current consumption per input
Switching element
Utilization category
Safety output
Operating current (Ie1)
(OSSD)
Voltage drop (Ud)
Test pulse duration
Test pulse interval
Switching element
Utilization category
Auxiliary output
Operating current (Ie2)
Voltage drop (Ud)
Switching frequency (f)
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Minimum operating current (Im)
OFF-state leakage current (Ir)
Mechanical
Fixing screws
Tightening torque of fixing screws
Material
Weight
RFID
125 kHz
-6 dBm max.
Type 4
D41D-1: High (individual coding)
D41D-2: High (individual coding, No limitation)
D41D-A1, D41D-A2, D41D-A3
100 ms max.
200 ms max.
2 s max.
12 mm
(lateral actuation: 9 mm)
10 mm (-10 to 60°C)
6 mm (-10 to 60°C, lateral)
8 mm (-25 to 65°C)
4 mm (-25 to 65°C, lateral)
18 mm
(lateral actuation: 15 mm)
<2.0 mm
<0.5 mm
24 VDC (-15%/+10%)
(stabilized PELV-power supply)
35 mA
III
3
(UL certification is 2)
100 A
2 A max.
1.0 ms max.
100 ms min.
5 mA
PNP type, short-circuit proof
DC-12: 24 VDC (Ue)/0.25 A (Ie)
DC-13: 24 VDC (Ue)/0.25 A (Ie)
0.25 A max.
<1 V
1.0 ms max.
1,000 ms
PNP type, short-circuit proof
DC-12:24 VDC (Ue)/0.05 A (Ie)
DC-13:24 VDC (Ue) /0.05 A (Ie)
0.05 A max.
<2 V
1 Hz
32 VDC
0.8 kV
0.5 mA
<0.5 mA
4 × M4 (Refer to the outline drawing for the actuator)
0.8 N·m (Refer to the outline drawing for the actuator)
Thermoplastic PBT (enclosure)
Unit: <50 g, Package: <110 g