Omron D41D Manual page 15

High-coded non-contact safety door switch
Hide thumbs Also See for D41D:
Table of Contents

Advertisement

Mounting
The mounting holes provide for a mounting by means of M4 screws (max. tightening torque 0.8 N•m).
The product can be mounted in any position. The minimum bend radius of the -025-type cable is 25 mm.
The active areas of the safety door switch and the actuator have to face each other.
The safety door switch must only be used within the assured operating distances ≤ Sao and ≥ Sar.
To avoid any interference inherent to this kind of system and any reduction of the operating distances, please observe the following guidelines:
• See the figures below for the minimum distances between two safety door switches and other systems of the same frequency (125 kHz).
50
109
90
100
[Unit: mm]