Troubleshooting
Error
Errors that, which no longer guarantee the function of the safety
door switch (internal errors) cause the safety outputs to be
disabled within the risk time.
After the rectification of the error, the error message is reset by
opening the corresponding guard door.
Error warning
The auxiliary output can also be used to detect clearance
variations between the safety door switch and the actuator in the
same way as the yellow LED.
An active fault is visualized by the red LED and causes the
auxiliary output to be disabled. The safety outputs are disabled
after a maximum of 30 minutes if the fault is not rectified. This
signal combination, auxiliary output disabled and safety channels
still enabled, can be used to stop the production process in a
controlled manner.
Table 1: Diagnostic information for safety door switch with auxiliary output
Status of switch
Supply voltage
Actuated
Actuated in limit area
Error warning,
switch actuated
Error
Teach actuator
Tampering protection
time *1
Error in input circuit
X1 and/or X2
Error in input circuit
X1 and/or X2
*1. Refer to Teaching.
16
LEDs
Green
Red
Yellow
On
Off
Off
On
Off
On
Flashes
On
Off
(1Hz)
Off
Flashes
On
Off
Flashes
On
Off
On
Flashes
Flashes
Off
Off
Flashes
Off
Off
(1Hz)
Flashes
Off
On
(1Hz)
LED indication (red)
1 flash pulse
2 flash pulses
3 flash pulses
4 flash pulses
5 flash pulses
Continuous red
Safety
Auxiliary
outputs
output
Y1, Y2
0 V
0 V
Voltage on
The yellow LED always signals the presence of an
24 V
24 V
actuator within range.
The safety door switch must be adjusted before
24 V
the distance to the actuator increases and before
24 V
pulsed
the safety outputs are disabled, thus stopping the
machine.
When the error warning is not rectified within 30
0 V
24 V
minutes, the safety outputs are disabled.
0 V
0 V
Refer to table with flash codes
0 V
0 V
Safety door switch in teaching mode
0 V
0 V
10 minutes pause after re-teaching
0 V
0 V
When door is open
24 V
0 V
When door is closed
Error cause
Error output Y1
Error output Y2
Cross-wire short
between Y1 and Y2
Ambient temperature too high
Incorrect or defective actuator
Internal fault, with yellow
flashing teaching procedure
Note