●4.Error end state management
No.
Overview
4.1.
Error end processing
4.2.
Response code setting
Additional Information
Refer to 9.8 Error Processing in this document for response codes.
Description
Turns ON the error end flag when an error end of the
program is determined in 2.3 Normal/error detection
processing.
If an error occurs, sets the corresponding response
code in the response code storage area.