4.3
Service Positions
This chassis has several predefined service positions, for
better accessibility. They are explained below in more detail.
4.3.1
Solder Side 'I/O 3rd SCART' panel (for PV02 styling - 9319
sets)
2
4
3
1680
Figure 4-5 Service position 1
To remove or access the 'I/O 3rd SCART' panel, do the
following:
1. Remove the fixation screw (1) (if present).
2. Release the two pegs (2).
3. At the same time, pull the complete module away from the
LSP bracket (3). It hinges in the LSP bracket.
4. To remove the panel, disconnect the flat-cables, and
remove the four panel screws (4).
4.3.2
Component Side LSP
SSB top-bracket
SSB
AUTO-SCAVEM
bracket
CONNECTOR SUPPORT
bracket
1
Bottom tray
2
Figure 4-6 Service position 2
For better accessibility of the LSP, do the following (see figure
above):
1. Remove the LSP-bracket from the bottom tray by pulling it
backwards.
2. Hook the bracket in the first row of fixation holes of the
bottom tray. In other words, reposition the bracket from (1)
to (2).
1
4
E_14950_018.eps
LOT - bracket
LSP
1
2
CL 26532041_065.eps
Mechanical Instructions
4.3.3
Solder Side LSP
2
2
240304
To get access to the bottom side (solder side) of the LSP, do
the following (see figure above):
1. Remove the DAF-module (see paragraph 'DAF Assy/
Panel' below).
2. To disconnect the degaussing coil from the LSP, remove
the cable from connector 1502 (1).
3. Release the wiring from their fixation clamps, in order to get
room for repositioning the LSP.
4. Flip the LSP 90 degrees clockwise (2), and place it in the
fixation hole at the left side of the bottom tray (3).
4.3.4
Small Signal Board (SSB)
110402
Caution:
Always switch the set completely "OFF" (disconnected the
mains cord) before you remove or replace the SSB.
As the 5V2 standby voltage is always present (while the set is
switched "ON", in "standby" or in "Protection" mode) on the
SIMM connector, it is very risky to remove the SSB in this
situation, because the risk of short circuiting is very great.
In fact, there is no predefined service position for the SSB. Most
test points are located on the A-side (side that is facing the
tuner). If you have to replace ICs, you must take the complete
SSB module out of the SIMM-connector.
Note: For good access to the A-side, it is necessary to remove
the Auto-SCAVEM bracket (at the left side of the SSB).
Remove the two fixation screws at the bottom by the Auto-
EM5.2E AA
3
Figure 4-7 Service position 3
4.
EN 9
1
1502
CL 26532041_066.eps
110402