3
3.1
First-time use/
charging batteries
Operation/discharging
3.2
3.2.1
Charging the battery
by USB-C port on
device
Batteries
Batteries
Operating Principles
The battery must be charged before using it for the first time because it is
•
delivered with an energy content as low as possible.
The permissible temperature range for charging is from 0 °C to
•
+40 °C/+32 °F to +104 °F. For optimal charging, we recommend charging
the batteries at a low ambient temperature of +10 °C to +20 °C/+50 °F to
+68 °F if possible.
It is normal for the battery to become warm during charging. Using the
•
chargers recommended by Leica Geosystems, it is not possible to charge
the battery once the temperature is too high.
For new batteries or batteries that have been stored for a long time
•
(> three months), it is effectual to make only one charge/discharge cycle.
For Li-Ion batteries, a single discharging and charging cycle is sufficient.
•
We recommend carrying out the process when the battery capacity indic-
ated on the charger or on a Leica Geosystems product deviates signific-
antly from the actual battery capacity available.
The batteries can be operated from −20 °C to +55 °C/−4 °F to +131 °F.
•
Low operating temperatures reduce the capacity that can be drawn; high
•
operating temperatures reduce the service life of the battery.
CAUTION
Connecting the charger improperly may cause serious damage to the device.
Any damage caused by misuse is not covered by the warranty. Use only Leica-
approved chargers, batteries, and cables. Unapproved chargers or cables can
cause the battery to explode or damage the device.
Charging the Battery
Charging the Battery by USB Port on Device
Charge the battery when the battery icon in the status bar is flashing
☞
or before the first use.
1.
Open the lid (a) and plug the cable into the port of the device (b).
2.
Plug the end of the USB-C cable into one of the provided adaptors.
Select the appropriate adapter for your country.
7