Telescopic kelly bar assembly
4.2.2
To mount the telescopic kelly bar one must prepare a hole (preferably coated)
in the ground, at least 0.5 [m] deep, which must be closed appropriately when
it is not used.
Proceed as follows:
• wear work gloves and a protective helmet;
• position the kelly bar to be mounted with suitable handling means,
using the connection loop of the main winch cable and making sure that
the kelly bar is not released;
• position the machine near the hole;
• position the the machine with the mast in the vertical position at
maximum height and aligned with the hole in the ground;
• disengage the descent limit switch of the main winch;
• connect the cable to the swivel joint using the pin 2
;
fig.3.2.3.1
• pull the cable so that the kelly bar slowly reaches a vertical alignment;
control kelly bar ascent until it has completed its stroke;
remount the Kelly drive, the springs and the 4 self-locking nuts;
tighten them so that they ensure the same pretensioning to the 4
springs
fig.4.2.2.1
• close the hole with the cover again
MAINTENANCE ON URGENT FAULTS OF THE DRILLING M.
Chapter 4
;
Fig.4.2.2.1
.
and
fig.4.2.1.1
4-3