Measuring port "M1" (1)
Measuring port "M2" (2)
Pump port "P" (3)
Tank port "T" (4)
Accumulator port "S" (5)
5.3.2 Hydraulic connections types 0532VAW20 and 0532VAW32
0532VAW20_4
1
3
0532VAW32_4
3
Fig. 9: Hydraulic connections types 0532VAW20 and 0532VAW32
(illustrated without shut-off cock)
1 Measuring port "M1"
2 Measuring port "M2"
3 Pump port "P"
Measuring port for pressure monitoring (see circuit diagram).
Measuring port for pressure monitoring (see circuit diagram).
Pump port for filling the hydraulic accumulator with oil.
Via the tank port, the oil is returned to the tank on manual or electrical relief of the
hydraulic accumulator (discharge line) in case of inadmissible overpressure.
Via the accumulator port, the hydraulic accumulator is connected to the accumulator
shut-off block.
RE 50129-B/02.19, Accumulator shut-off block type ABZSS, 0532VAW, Bosch Rexroth AG
Product information
5
2
5
4
4 Tank port "T"
5 Accumulator port "S"
29/64
4
2
1