Electrically Connecting The Accumulator Shut-Off Block - Bosch Rexroth ABZSS Operating Instructions Manual

Accumulator shut-off block
Table of Contents

Advertisement

Remove any protective plugs.
Check the hydraulic connections and lines for cleanliness.
Make sure that the line connections contain the intended seals.
If necessary, secure O-rings against slipping using installation grease.
Connect the lines for pump port "P" / pump ports "P1" and "P2" and the tank
port "T" according to the specifications of the system/machine manufacturer.
– Observe the tightening torques of the fitting manufacturer.
Connect the hydraulic accumulator at the accumulator port "S" to the
accumulator shut-off block.
Connect the measuring ports M1 and M2 to a pressure gauge.
The hydraulic supply of the accumulator shut-off block is now established.

7.5.4 Electrically connecting the accumulator shut-off block

Incorrectly connected electrical components!
Damage to property!
Connect the electric components according to the electric circuit diagram and
the pin assignment.
Make sure that electrical components are connected by a specialized electrician.
For electrical connection of the accumulator shut-off block, the following work steps
have to be performed:
Before the assembly, de-energize the electrical control system.
Familiarize with the position of the electrical connections.
– Also observe chapter 5.4 "Electrical connections".
Regarding the electric wiring at the control block accumulator shut-off block,
observe the data sheets of the electric components.
Check the electrical connections for cleanliness.
Connect the accumulator shut-off block according to system or machine
manufacturer specifications.
The power supply of the accumulator shut-off block is connected.