• Check that the blower's rotational direction is in accordance with the arrow on
the blower hood.
NOTE: The blower blows even if the rotational direction is wrong, but capacity will be
less than 25%.
Smell of melted plastic and smoke formation
• Overfilling or stoppage in transport pipes, cyclone, dust filter or collecting
container.
The blower functions easily and the granulator grinds plastic into powder and
subsequently into a hot mass.
WARNING! If the granulator is turned off, the result will be hardened lumps
in the cutter house.
Read the section on hardened lumps in the cutter housing.
WARNING! Risk of fire in the cutter house.
NOTE: Do NOT turn off the granulator. Try to attend to, release and evacuate the stop-
page in transport pipes, cyclone, dust filter or collecting container.
Then clean and empty the granule bin, transport pipes, cyclone, dust filter and col-
lecting container.