EXTERNAL CONNECTIONS
External connections are connected on terminal blocks
X28, X29 and X30 on the PCB (AA2).
BT1 14
BT50 13
BT25 12
AUX9 11
AUX8 10
AUX7 9
AUX6 8
AUX5 7
AUX4 6
AUX3 5
AUX2 4
AUX1 3
+5V 2
0-5V 1
-X28
Sensors
Outside sensor
The outdoor sensor (BT1) is placed in the shade on a
wall facing north or north-west, so it is unaffected e.g.
by the morning sun.
The outdoor sensor is connected to terminal block AA2-
X28:14 and to any input on terminal block AA2-X29.
If a conduit is used it must be sealed to prevent condens-
ation in the sensor capsule.
AA2-X28
BT1
14
BT50
13
BT25
12
AUX9
11
AUX8
10
AA2-X29
Temperature sensor, hot water charging
The temperature sensor, hot water charging (BT6) is
placed in the submerged tube on the water heater.
Connect the sensor to terminal block AA2-X28:11 (or to
one of the other selectable AUX inputs) and to any input
on terminal block AA2-X29.
Settings for hot water are made in menu 2 "Hot water".
AA2-X28
BT6
11
AUX8
10
AUX7
9
AUX6
8
7
AUX5
AA2-X29
20
Chapter 5 | Electrical connections
AA2
POWER
X27
ERROR
12
BE3
INT COM
EXT COM
11
BE2
CPU
10
BE1
PWM1
9
GND
PWM0
8
+5V
X30
7
0-5V
6
OT−
5
OT+
4
A
3
B
2
+12V
X29
1
GND
-X29
-X30
X28
BT1
BT6
Temperature sensor, hot water top
A temperature sensor for hot water top (BT7) can be
connected to S1155PC to show the water temperature
at the top of the tank (if it is possible to install a sensor
at the top of the tank).
Connect the sensor to terminal block X28:10 (or to one
of the other selectable AUX inputs) and to any input on
terminal block AA2-X29.
AA2-X28
BT7
AUX8
10
AUX7
9
AUX6
8
AUX5
7
6
AUX4
AA2-X29
Temperature sensor, external flow line
Connect temperature sensor, external supply line (BT25)
to terminal block AA2-X28:12 and to any input on termin-
al block AA2-X29.
AA2-X28
BT1
14
BT50
13
BT25
12
AUX9
11
AUX8
10
AA2-X29
BT25
NIBE S1155PC