Nibe S1155PC Installer Manual page 44

Ground source heat pump
Hide thumbs Also See for S1155PC:
Table of Contents

Advertisement

Caution
If you deselect "addition" it may mean that in-
sufficient hot water and/or heating in the ac-
commodation is achieved.
MENU 4.2 - PLUS FUNCTIONS
Settings for any additional functions installed in S1155PC
can be made in the sub menus.
MENU 4.2.3 - SG READY
Here, you set which part of your climate system (e.g.
room temperature) will be affected on activation of "SG
Ready". The function can only be used in mains networks
that support the "SG Ready" standard.
Affect room temperature
With low price mode on "SG Ready" the parallel offset
for the indoor temperature is increased by "+1". If a room
sensor is installed and activated, the desired room
temperature is instead increased by 1 °C.
With over capacity mode on "SG Ready" the parallel
offset for the indoor temperature is increased by "+2".
If a room sensor is installed and activated, the desired
room temperature is instead increased by 2 °C.
Affect hot water
With low price mode on "SG Ready", the stop temperat-
ure for the hot water is set as high as possible with
compressor operation only (immersion heater not per-
mitted).
In the case of overcapacity mode on "SG Ready", the
hot water is set to large demand mode (immersion
heater permitted).
Affect cooling
With low price mode of "SG Ready" and cooling opera-
tion the indoor temperature is not affected.
With overcapacity mode on "SG Ready" and cooling op-
eration, the parallel offset for the indoor temperature is
decreased by "-1". If a room sensor is installed and activ-
ated, the desired room temperature is decreased instead
by 1 °C.
NOTE
The function must be connected to two AUX
inputs and be activated in menu 7.4 "Selectable
in/outputs".
44
Chapter 9 | Control - Menus
MENU 4.2.5 - SMART PRICE ADAPTION™
Range
Here you select where (which zone) S1155PC is in-
stalled.
Contact your electricity supplier to find out which
zone digit to enter.
Affect room temperature
Setting range: 1 - 10
Affect hot water
Setting range: 1 - 4
Affect cooling
Alternative: on/off
Degree of effect
Setting range: 1 - 10
This function can only be used if your electricity supplier
supports Smart price adaption, if you have an hourly
tariff agreement and an active myUplink account.
Smart price adaption™ moves the heat pump's consump-
tion over 24 hours to periods with the cheapest electri-
city tariff, which gives savings for hourly rate based
electricity contracts. The function is based on hourly
rates for the next 24 hours being retrieved via myUplink
and therefore an internet connection and an account for
myUplink are required.
You can choose which parts of the installation are to be
affected by the electricity price and to what extent; the
higher value you select, the greater the effect the elec-
tricity price has.
NOTE
A value that is set high may result in increased
savings, but may also affect the comfort.
MENU 4.4 - WEATHER CONTROL
Activate weath. contr.
Setting range: on/off
Factor
Setting range: 0 – 10
You can select whether you want S1155PC to adjust
the indoor climate based on the weather forecast here.
You can set factor for outdoor temperature. The higher
the value, the greater the effect from the weather fore-
cast.
NIBE S1155PC

Advertisement

Table of Contents
loading