Nibe S1155PC User Manual

Ground source heat pump
Hide thumbs Also See for S1155PC:

Advertisement

Quick Links

UHB EN 1927-1
531124
Ground source heat pump
NIBE S1155PC/S1255PC
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Nibe S1155PC

  • Page 1 UHB EN 1927-1 USER MANUAL 531124 Ground source heat pump NIBE S1155PC/S1255PC...
  • Page 2 S1155PC: This function page is only visible in installations with a water heater. IN THE EVENT OF DISTURBANCES IN COMFORT If you experience a disturbance in comfort of any kind, there are various measures you can take yourself before...
  • Page 3: Table Of Contents

    Display unit Navigation Menu types Menu system 4 myUplink Specification Connection Range of services Mobile apps for myUplink 5 Maintenance of S1155PC/S1255PC Regular checks Saving tips 6 Disturbances in comfort Info-menu Manage alarm Only additional heat Item register Contact information...
  • Page 4: Important Information

    1.9.1.1 heating curve (curve slope) Serial number must always be given Certification that the installation is carried out according to instructions in the accompanying installer manual and applicable regulations. Date ______________________________ Signed __________________________________________ Chapter 1 | Important information NIBE S1155PC/S1255PC...
  • Page 5: Serial Number

    Serial number The serial number can be found at the bottom right on S1155PC/S1255PC, in the display on the home screen "Product overview" and on the type plate. Caution You need the product's (14 digit) serial number for servicing and support.
  • Page 6: Heat Pump Function

    The brine can also be circulated via a mixing valve to a heat exchanger. There the brine cools the heating system's water so that comfort cooling can be maintained during the hotter periods of the year. Chapter 2 | Heat pump function NIBE S1155PC/S1255PC...
  • Page 7: Control - Introduction

    For hard switch off: press and hold the on/off button for • lights red in the event of a deployed alarm. 5 seconds. • is blue when S1155PC/S1255PC is switched off. To activate emergency mode when S1155PC/S1255PC is running: press the on/off button (SF1) once and select •...
  • Page 8: Navigation

    FACTORY SETTING Navigation Factory set values are marked with *. S1155PC/S1255PC has a touchscreen where you simply Your installer may have chosen other values that suit manage the navigation by pressing and dragging with your system better. your finger. SELECT...
  • Page 9 Set temperature Works to set temperature The drop-down menu shows the current status for S1155PC/S1255PC, what is in operation and what Press the boards to adjust desired value. On some S1155PC/S1255PC is doing at the moment. function pages, you drag up and down with your finger to obtain more boards.
  • Page 10: Menu System

    (accessory is required). Menu 2 – Hot water 13.45 3 October You make settings for hot water operation here. S1155PC: This menu is only visible in installations with Your system is working properly. Do you want help making changes? water heaters.
  • Page 11: Myuplink

    • wireless network or network cable The base level allows you to monitor the system, man- age alarms and read diagrams containing information • Internet connection to which S1155PC/S1255PC can for the last month. be connected If you want to read older information, as well as receive •...
  • Page 12: Maintenance Of S1155Pc/S1255Pc

    The thermo- stats slow the flow in the heating system, which Your heat pump is basically maintenance free and S1155PC/S1255PC wants to compensate by increas- therefore requires minimal care after commissioning. ing the temperature. It will then work harder and However, it is recommended that you check your install- consume more energy.
  • Page 13: Disturbances In Comfort

    S1155PC/S1255PC cannot S1155PC: This part of the fault-tracing chapter only ap- remedy itself. On the display, you can see what type of plies if a water heater is installed in the system.
  • Page 14 1.30.1 (heating curve) may need adjusting downwards. – If the hot water usage has been low, S1155PC/S1255PC will produce less hot water than normal. Activate "Tempor- • External switch for changing the room temperature arily more hot water"...
  • Page 15: Only Additional Heat

    To switch off, restart: press the on/off button once. This brings up a menu with various options. To activate emergency mode when S1155PC/S1255PC is switched off: press and hold the on/off button for 5 seconds. (Deactivate the emergency mode by pressing once.)
  • Page 16: Item Register

    Troubleshooting, 13 Help menu, 8 Important information Installation data, 4 Serial number, 5 Info menu, 13 Installation data, 4 Maintenance of S1155PC/S1255PC, 12 Regular checks, 12 Saving tips, 12 Manage alarm, 13 Navigation Help menu, 8 Only additional heat, 15...
  • Page 19: Contact Information

    Tel: +46 (0)433-27 3000 kuzmin@evan.ru info@nibe.se nibe-evan.ru nibe.se SWITZERLAND NIBE Wärmetechnik c/o ait Schweiz Industriepark, CH-6246 Altishofen Tel. +41 (0)58 252 21 00 info@nibe.ch nibe.ch For countries not mentioned in this list, contact NIBE Sweden or check nibe.eu for more information.
  • Page 20 WS release date: 2019-06-11 06:11 Publish date: 2019-07-04 11:33 This manual is a publication from NIBE Energy Systems. All product illustrations, facts and data are based on the available information at the time of the publication’s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this manual.

This manual is also suitable for:

S1255pc