Nibe S1155PC Installer Manual page 54

Ground source heat pump
Hide thumbs Also See for S1155PC:
Table of Contents

Advertisement

OPERATING PRIORITY
Pool 1
MENU 7.1.10.2 - AUTO MODE SETTINGS
Start cooling
Setting range: 15 – 40 °C
Stop heating
Setting range: -20 – 40°C
Stop additional heat
Setting range: -25 – 40°C
Filtering time
Setting range: 0 – 48 h
Filtering time, cooling
Setting range: 0 – 48 h
Stop heating, Stop additional heat: In this menu, you set
the temperatures that the system is to use for control
in auto mode.
Caution
In systems where heating and cooling share
the same pipes, "Stop heating" cannot be set
higher than "Start cooling" if there is no cool-
ing/heating sensor.
MENU 7.1.10.3 - DEGREE MINUTES SETTING
Cooling auto
Setting option: on/off
Degree minutes are a measurement of the current
heating requirement in the house and determine when
the compressor respectively additional heat will
start/stop.
MENU 7.2 - ACCESSORY SETTINGS
The operating settings for accessories that are installed
and activated are made in the sub-menus for this.
MENU 7.2.1 - ADD/REMOVE ACCESSORIES
Here, you tell S1155PC which accessories are installed.
54
Chapter 9 | Control - Menus
Min
Hot water
Heating
Pool 1
Pool 2
Cooling
To identify connected accessories automatically, select
"Search for accessories". It is also possible to select ac-
cessories manually from the list.
MENU 7.2.19 - EXTERNAL ENERGY METER
Here, you make settings for the energy meter.
Pulsed energy meter
Set mode
Setting range: energy per pulse / pulses per kWh
Energy per pulse
Setting range: 0 – 10000 Wh
Pulses per kWh
Setting range: 1 – 10000
Pulsed energy meter
The energy meter(s) is used to send pulse signals every
time a certain amount of energy has been consumed.
energy per pulse: Here you set the amount of energy
to which each pulse will correspond.
pulses per kWh: Here, you set the number of pulses
per kWh that are sent to S1155PC.
MENU 7.3 - MULTI-INSTALLATION
In the sub-menus here, you make settings for the heat
pumps that are connected to S1155PC.
MENU 7.3.1 - CONFIGURE
Multi-installation
Alternative: on/off
System settings
Alternative: Main Unit / Heat Pump 1 – 8
Multi-installation: Here you specify whether S1155PC
is part of a multi-installation (one installation with several
connected heat pumps).
System settings: Here, you specify whether S1155PC
is the multi-installation's main unit. In systems with only
one heat pump, S1155PC will be the main unit. If there
is another main unit in the installation, you enter the ID
that S1155PC will have.
Search installed heat pumps: Here, you can search for,
activate or deactivate connected heat pumps.
Caution
In multi-installations, each heat pump must
have a unique ID. You enter this for each heat
pump that is connected to S1155PC.