Nakanishi AL-M1203BS2 Operation Manual page 3

Air line kit
Table of Contents

Advertisement

CAUTION
Use of dry air
Using compressed air containing excessive moisture could result in malfunction or failure of
the spindle and air motor. If excessive moisture or condensation are found in Air Filter Bowl, it
will be necessary to install a dryer and larger Air Filter on the primary side of the Air Line Kit to
prevent and remove excessive moisture.
Draining
Be sure to drain moisture and condensation from Air Filter Bowl regularly to avoid moisture
being carried to the spindle and air motor.
Installation Location
Place this Air Line Kit on a Àat and level surface.
If mounting on a wall, check if the wall is Àat, and securely mount the Air Line Kit in a
horizontal direction.
Handling
When removing the Bowl or Oil Reservoir for cleaning, carefully remove them as not to cause
damage to them.
Connection of Solenoid Operated Valve and Alarm Buzzer
Do not use the power voltage of the more than DC+24V, this will cause damage to the Solenoid
Operated Valve or Alrm Buzzer of the Air Line Kit.
Be sure to use the power source voltage of DC+24V.
CAUTIONS for STORAGE, INSTALLATION and OPERATION
Do not use the Air Line Kit where corrosive gasses, chemicals, seawater, water, oils or steam
exist.
Do not place in direct sunlight.
Do not use where the Air Line Kit is subject to vibration or repetitive shock.
Do not use where a heat source or radiated heat exist.
To conform to " STORAGE, INSTALLATION and OPERATION " (Refer to " 3. SPECIFICATIONS ").
2 . FEATURES
① The Air Filter traps small amounts of water and impure substances from the input air supply. This Air Line Kit is
not intended to be used or replace an Air Dryer.
② Provides stable air Àow and proper air pressure to the tool by using an adjustable Regulator.
③ The oil mist supplied from lubricator to the Air Tool and Reducer will prolong their service life due to lubrication
and the reduction of heat and friction.
④ Equipment with " Auto Drain Mechanism ", automatically draining the drain in the ¿lter.
⑤ The Solenoid Operated Valves (DC+24V : 2pcs) can be operated by an M-Code Signal from the CNC machine
tool. This Air Line Kit allows for operation of (2) two air motors.
⑥ Equipped with a low lubrication oil level " Alarm Buzzer ", signaling the need to ¿ll with Lubricating Oil.
12

Advertisement

Table of Contents
loading

Table of Contents