Hyundai HY-CLM09KR-001 User Manual page 38

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 24
for holding the total system charge is available. All cylinders to be used are designated for the recovered
refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant).
Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order.
Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment
that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of
calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free
disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory
working order, has been properly maintained and that any associated electrical components are sealed to prevent
ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder,
and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not
in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable
level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process
shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor
body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried
out safely.
Fuse parameters of the machine
T
ype: 5ET or SMT
Voltage: 250V
A. Unit Storage:
1:Unscrew the drainage cover, unplug the water plug, and discharge the water in the water pan into other water
containers or directly tilt the body to discharge the water into other containers.
2:Turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage
pipe becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.
3:Turn off the machine, unplug the power plug, and wrap the power cord around the wrapping post; install the
water plug and the drainage cover.
4:Remove the exhaust pipe and keep it properly.
5:Cover the air conditioning with a plastic bag. Put the air conditioning in a dry place, keep it out of the
reach of children, and take dust control measures.
6:Remove batteries of the remote control and keep them properly.
Note: ensure that the body is placed in a dry place and keep all machine components properly.
IX.Troubleshooting
Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure
of the warranty card, and may cause damage to users or their properties.
Problems
Reasons
There is no electricity.
The overflow indicator displays "FL".
The air
The ambient temperature is too low or
conditioning
too high
does not work.
In cooling mode, the room temperature
is lower than the set temperature; in
heating mode, the room temperature is
higher than the set temperature.
Current: 3.15 A
Licensed by HYUNDAI Corporation Holdings, Korea
Imported/distributed by MARKET MAKER GROUP S.A.
Solutions
Turn it on after connecting it to a socket with
electricity.
Discharge the water inside.
Recommend to use the machine in at the
temperature of 7-35 ℃ (44-95 ℉).
Change the set temperature.
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents