Summary of Contents for Hyundai WSH-071NBE

  • Page 1 SERVICE MANUAL...
  • Page 2 CONTENTS 1. LIGHT SERIES............1 2. STANDARD SERIES............44 3. DELUX SERIES............166 4. PRESTIGE SERIES............222...
  • Page 3: Light Series

    LIGHT SERIES...
  • Page 4 WSH-071/091NBE T y p e o f c o n t e n t s 1. OPERATION RANGE 2. SPECIFICATION 3. INSTALLATION 4. ELECTRICAL DATA 5. CONTROL MODE 6. TROUBLE SHOOTING 7. CHECKING COMPONENTS 8. PART LIST AND EXPLODE VIEW...
  • Page 5 Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp Maximum 32℃ D.B./23℃ W.B. 43 ℃ D.B./26℃ W.B. COOLING 21℃ D.B./15℃ W.B. 21 ℃ D.B./15℃ W.B. Minimum Maximum 27℃ D.B./18℃ W.B. 24℃ D.B./18℃ W.B. HEATING Minimum 20℃ D.B/≤15℃ W.B -7℃ D.B./-8℃ W.B.
  • Page 6 2-1. Unit specifications Model No. WSH-091NBE Type T1, H/P, ON/OFF Ratings Cooling Capacity 2640 Heating Capacity 2790 Rated Input-Cooling Rated Input-Heating Moisture Removal L/H.r Air Circulation m3/h EER for Cooling 3.22 COP for Heating 3.62 Energy Class Cooling Energy Class Heatling Refrigerant R410A...
  • Page 7 3 Speed and Auto Indoor Fan Control Vertical Auto Swing Louver Manual Adjustable Horizontal Swing Louver Sleep Operation Smart Function Super Function Compressor Indicator Auto Restart Dimmer Other Dimensions Indoor Unit 750×250×190 WxHxD (mm) Outdoor Unit 715×482×240 Indoor Unit Net Weight (Kg) Outdoor Unit Indoor Unit 800×325×245...
  • Page 8 2-2-2 OUTDOOR FAN MOTOR ELECTRIC PERFORMANCE PARAMETER Motor model DG13Z1-10(A) Rated power source 208~240V 50Hz 1.5μF/450V Fan capacitor Poles Rated load output(W) Ambient temperature(℃) -5℃~+43℃. 2-2-3. COMPRESSOR ELECTRIC PERFORMANCE PARAMETER Compressor model 44A203BK&FJKC Compressor type Rotary Motor type. Single phase induction motor Starting type Permanent split capacitor Motor...
  • Page 9 1、How to choose an air conditioner: a. Choice for reference: 150-170W/㎡ for average rooms; b. Choice for reference: 160-200W/㎡ for small size offices; c. Choice for reference: 220-350W/㎡ for restaurants; d. Choice for reference: 200-300W/㎡ for entertaining venues; e. Choice for reference: 220-280W/㎡ for the top floor. Note:1W = 3.412btu.
  • Page 10 4-1-2. OUTDOOR 4-3. Sensor parameter 1. THE PARAMETER OF THE COIL AND INDOOR SENSOR: (R =15K±2%) T(℃) R(KΩ) T(℃) R(KΩ) V(v) V(v) 152.5 4.5522388 E8 11.99 2.221193 143.9 4.528005 11.47 2.1666037 6E 135.8 4.5026525 E6 10.98 2.113164 128.3 4.4766225 E4 10.51 2.0599765 69 121.1 4.4489346 E3 10.06 2.0071828 66...
  • Page 11 73.52 4.1527338 D4 6.875 1.5714286 50 69.05 4.107674 6.597 1.5272955 4E 66.01 4.0741884 D0 6.333 1.4843201 4C 62.58 4.033256 6.08 1.4421252 4A 58.34 3.9773657 CB 5.838 1.4008062 47 56.29 3.947959 5.608 1.3606366 45 53.41 3.9036691 C7 5.387 1.3211851 43 50.69 3.8582737 C5 5.177 1.2828964 41 48.12 3.8117871 C2 4.976 1.2454946 40...
  • Page 12 Chapter 1 System Description 1. System control diagram Indoor control circuit Remote Display Remote control Indoor Room temperature sensor Indoor fan motor circuit Indoor pipe temp. sensor Indoor air flow direction motor Outdoor temperature sensor Outdoor fan motor (only 18K,24k HEAT PUMP) Compressor 4-way reversing valve Outdoor control circuit...
  • Page 13 3. System Signal Input a) Remote control signal, room temperature signal, coil pipe temperature signal, “ON/OFF” signal, Filter Monitor reset signal 4. System Signal Output 4.1 H/C split unit: Air flow direction motor(step motor), indoor fan motor(PG regulating motor or tapped regulating motor), digital tube and LED display, Electrical heating signal, Buzzer, Outdoor fan motor, Coil of the 4-way reversing valve, Compressor( or AC contactor).
  • Page 14 (3)The appliance is ceased for 3 min delay protection when the auto-restart after blankout. (4)The appliance is ceased for 5 sec delay protection to perform the other operation after it receive the signal of specific operation, but no any delay for the response.
  • Page 15 High Medium Heat Refer to the parameter list(Heat Pump) Cooling Refer to the parameter list According to the Dry mode Fan only the RPM same as Heating mode 1.4 Indoor louver swing control 1.5 Overcooling protection control (only available for Cooling) 1.6 Anti-cold air system (only available for Heat Pump) 1.7 Auto-Defrost (only available for Heat Pump) 1.8 Overheating protection of heater exchange (only available for Heat...
  • Page 16 3. Control panel and display 3.1 Digital Tube display( 3.2 LED indicator description 3.2.1 Running Indicator: It lights in the running operation and flashing in the Defrost mode.(except the Sleep and Dimmer mode) 3.2.2 Timer Indicator: It lights in the Timer ON condition. (except the Sleep and Dimmer mode) 3.2.3 Sleep Indicator It lights in the Sleep mode.
  • Page 17 4. Operation Mode The appliance could be operated under Heat, Cooling, Dry and Fan Only mode, and also the super, the smart operation mode 4.1 Fan Only Mode Operation During the appliance run in this mode, the compressor and outdoor fan stop, the indoor fan operate under the pre-setting of air volume, and the louver swing, and the indoor fan speed same as the Heating Mode.
  • Page 18 minutes, the compressor and outdoor fan motor will be turned ON. 4.2.5 Indoor fan operation (1) When room temperature is higher than 35℃, the compressor is ceased for 1 min then turn on, (when the compressor ceased for 3 min protection, the indoor fan should be turn on immediately) (2)...
  • Page 19 operation. If 3 minutes elapses after starting, the appliance will sense the intake air temperature and minus 2℃ as the setting temperature and operate in Cooling mode, and the indoor motor speed is low. During this operation, the air flow direction could be set but the air volume is unavailable, and the setting temperature can only be adjusted by 2℃...
  • Page 20 35℃(#26) The setting air flow The setting air flow 30℃(#27) Extra-low Stop 25℃(#28) Stop When the appliance turn in the anti-cold air system in the Extra-LOW (Tapped motor set in LOW, sic passim) during the compressor operation, the louver swang to the Cool air protection position, the louver recovers to the original position after the air volume change to LOW.
  • Page 21 speed. 4.4.5 Overheating protection control When overloading occurs during the heating operation, this system controls the outdoor fan motor and compressor according to the indoor coil pipe temperature to prevent the overloading of the compressor and restrict the pipe pressure to rise up. When the indoor pipe temperature exceeds 53℃, the outdoor fan motor will be turned OFF, and when the indoor pipe temperature falls below 49℃, the outdoor fan motor recovers to ON;...
  • Page 22 (2) Cool only appliance a. When the room temperature exceeds 26℃, it will be ran in Cool mode, and the temperature is set to 26℃. b. When the room temperature exceeds 23℃, but not more than 26℃, it will be operated in the Dry mode. c.
  • Page 23 (2)Timer ON/OFF (3)Timer ON/OFF can be set available in turn. (4)The Timer accurate more than 97% (5)The Timer can be adjusted by 0.5 hour increase. (6)The OFF-Timer can be set when the appliance is in operation, the ON-timer can be set when the appliance is in suspension, and the Timer setting is display. 5.2 Sleep mode operation (1)The Sleep mode can only be set during Cool, Heat and Dry mode.
  • Page 24 indicators will be lit in 10 sec, then turn OFF except the Sleep light. 5.3 Self-diagnosis The room temperature and indoor pipe temperature are the important factor for the appliance operation, when the room temperature sensor broken or shorted is detected, it will set the room temperature at 23 ℃ , and the compressor will be cycled with power ON in 20 min and OFF in 3 min.
  • Page 25 Ο × × failure ★ temperature sensor of indoor heater exchange Ο Indoor EEPROM failure ★ ★ ★ Ο × Indoor fan motor failure 7,9,12,18K ★ ★ × The failure for Indoor ★ ★ ★ grounding protective Ο Ο × Overcooling protection 7,9=-1 12=-7 ★...
  • Page 26 parameter selection. 5.7 Auto-restart after blankout When the appliance loses power during the normal operation, it will recover with the last setting such as operation mode and temperature setting, except the air flow direction after power ON. When the appliance run in normal operation, the Emergent button is press and hold for over 1.5 sec, and the buzzer beep 2 times, the Auto-restart after blankout is available.
  • Page 27 6-1. Error codes 6-1-1.operating and display 6-1-2.Error codes: A. Indoor pipe temperature between 53.C<T<63.C: Outdoor fan motor will stop When the evaporator running. After Indoor pipe temperature is pipe temperature is lower than 49.C, the AC will restart normally. higher than 63 degree B.
  • Page 28 Outdoor fan motor is broken Replace outdoor fan motor Outdoor fan motor capacitor Replace capacitor is broken voltage between compressor terminals Repair control P.C.B the indoor unit voltage between compressor terminals Repair control P.C.B the indoor unit Repair electrical wiring voltage between The compressor does not...
  • Page 29 6-3. Checking procedure Note: Do not check indoor and outdoor units at the same time. Be sure to check them one by one. The machine does not function at all with remote controller and EMERGENCY button on the indoor unit. Correct power supply between “L”...
  • Page 30 The machine does not function with the remote controller. Push the ON/OFF button on the wireless remote controller. Are batteries of remote controller proper? Is transmitting signal of the remote controller active? Replace the batteries Replace the wireless with new ones. remote controller.
  • Page 31 The room is not cooled at all or not cooled enough in cooling operation. The room is not heated at all or not heated enough in heating operation. The compressor does not operate. Push the buttons EMERGENCY on the indoor unit. Refer to Trouble Suspension Table Measure the resistences of room temperature and indoor pipe temperature thermisters.
  • Page 32 7-1.Check parts unit 1. INDOOR FAN MOTOR .MOTOR EXAMINE AND REPAIR Circuit diagram BROWN BLACK YELLOW Test in resistance. TOOL: Multimeter. Test the resistance of the main winding. The indoor fan motor is fault if the resistance of main winding 0(short circuit)or∞(open circuit). Notes: Please don’t hold motor by lead wires.
  • Page 33 Please don’t plug IN/OUT the motor connector while power ON. Please don’t drop .Hurl or dump motor against hard material.Malfunction may not be observed at early stage after such shock.But it may be found later,This type of mishandling void our warranty. The wiring color of the motor may not be identical with the picture shows, please take the actual material as standard.
  • Page 34 TOOL: Multimeter. Test the resistance of winding. The stepper motor is fault if the resistance of winding 0(short circuit)or∞(open circuit). 7-2. Check others 1. FUSE Checking continuity of fuse on PCB ASS’Y. Remove the PCB ASS’Y from the electrical component box..Then pull out the fuse from the PCB ASS’Y (Fig.1) Fuse PCB Ass抷...
  • Page 35 8-1. Indoor unit 1. Exploded View 2. Part list PART CHINESE DRAWING NO. DESCRIPTION DESCRIPTION 1359261 G1K30/R00.01.01-00 底座部件 base parts 1339745 K33190002 挂墙板部件 installation plate assy 1276892 KT20P0-10 排水管 drainage hose 1222824 KT25F0-05 轴承座 bearing 1203627 RZA-2-2360-4-XX-0 导流板 air duct plate 1203661 RZA-2-2478-112-XX-0 卡板...
  • Page 36 1276586 G1C20/R00.05.01-02 显示盒 display box 1393142 K36430280-+KGK-94G1.03-00 显示板 display board 1326018 G1C20/R00.05.01-03-PET 膜片 film 1401634 G1K32/R00.02-02 显示膜片 display film 面板(图案)(不带 1401600 G1K32/R00.02-01(ZX) art cover without LOGO 商标) 1369208 +G1K30/R00.05-01 电器盒 elec joint box 控制板组件(不带 Contorl Board assembly without FC 1428717 KGK-C271(OEM268)-00 FC 功能)...
  • Page 37 2. Part list PART NO. DRAWING NO. CHINESE DESCRIPTION DESCRIPTION 1406865 W1M0K/R00.01.01-00 底座部件 base parts mounting plate (can not install the 1248461 W1A1L/00.01.01-03 安装板(不能安装阀罩) valve cover) mounting plate (can insrall the 1248010 W1A0D/R10.01.01-03 安装板(能安装阀罩) valve cover) 1415305 K37340403 冷凝器组件 condenser ASS'Y 1402542 W1M0N/R00.04-03 隔板...
  • Page 38 WSH-121NBE T y p e o f c o n t e n t s 1. OPERATION RANGE 2. SPECIFICATION 3. INSTALLATION 4. ELECTRICAL DATA 5. CONTROL MODE 6. TROUBLE SHOOTING 7. CHECKING COMPONENTS 8. PART LIST AND EXPLODE VIEW...
  • Page 39 Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp Maximum 32℃ D.B./23℃ W.B. 43 ℃ D.B./26℃ W.B. COOLING 21℃ D.B./15℃ W.B. 21 ℃ D.B./15℃ W.B. Minimum Maximum 27℃ D.B./18℃ W.B. 24℃ D.B./18℃ W.B. HEATING Minimum 20℃ D.B/≤15℃ W.B -7℃ D.B./-8℃ W.B.
  • Page 40: Power Supply

    2-1. Unit specifications Model No. WSH-121NBE T1, H/P, ON/OFF Type Ratings 3520 Cooling Capacity 3670 Heating Capacity 1090 Rated Input-Cooling 1015 Rated Input-Heating Moisture Removal L/H.r Air Circulation m3/h 3.23 EER for Cooling 3.62 COP for Heating Energy Class Cooling Energy Class Heatling R410A...
  • Page 41 3 Speed and Auto Indoor Fan Control Vertical Auto Swing Louver Manual Adjustable Horizontal Swing Louver Sleep Operation Smart Function Super Function Compressor Indicator Auto Restart Dimmer Other Dimensions Indoor Unit 750×250×190 WxHxD (mm) Outdoor Unit 715×482×240 Indoor Unit Net Weight (Kg) Outdoor Unit Packing Dimensions...
  • Page 42 2-2-2 OUTDOOR FAN MOTOR ELECTRIC PERFORMANCE PARAMETER Motor model DG13Z1-10(A) Rated power source 208~240V 50Hz 1.5μF/450V Fan capacitor Poles Rated load output(W) Ambient temperature(℃) -5℃~+43℃. 2-2-3. COMPRESSOR ELECTRIC PERFORMANCE PARAMETER Compressor model 44A263BK-FJKC Compressor type Rotary Motor type. Single phase induction motor Starting type Permanent split capacitor Motor...
  • Page 43 WSH 121NBE 8-1. Indoor unit 1. Exploded View 2. Part list PART DESCRIPTIO DRAWING NO. DESCRIPTION Q'TY N(CHINESE ) 1359261 G1K30/R00.01.01-00 base parts 底座部件 1339745 K33190002 installation plate assy 挂墙板部件 1276892 KT20P0-10 drainage hose 排水管 1222824 KT25F0-05 bearing 轴承座 1203571 RZA-2-2326-119-01-0 air duct plate 导流板...
  • Page 44 1276586 G1C20/R00.05.01-02 display box 显示盒 1393142 K36430280-+KGK-94G1.03-00 display board 显示板 1326018 G1C20/R00.05.01-03-PET film 膜片 1401634 G2C30/R00.02-03 display film 显示膜片 面板(图案)(不带 1401600 G1K32/R00.02-01(ZX) art cover without LOGO 商标) 1369208 +G1K30/R00.05-01 elec joint box 电器盒 Contorl board without FC 控制板组件(不带 1428750 KGK-C273(OEM267)-00 FC 功能)...
  • Page 45 PART DESCRIPTIO DRAWING NO. DESCRIPTION Q'TY N(CHINESE) 1406865 W1M0K/R00.01.01-00 base parts 底座部件 mounting plate(can not install the 安装板(不能安装 1248461 W1A1L/00.01.01-03 valve cover) 阀罩) mounting plate(can install the valve 安装板 (能安装阀 1248010 W1A0D/R10.01.01-03 cover) 罩) 1415263 K37340402 condenser ASS'Y 冷凝器组件 1402542 W1M0N/R00.04-03 separate plate 隔板...
  • Page 46: Standard Series

    STANDARD SERIES...
  • Page 47: Technical Specifications

    1. Technical specifications HSH-S071NBE Model COOLING HEATING Function Rated Voltage 220-240V ~ (230V) Rated Frequency 50Hz 2200 2380 Total Capacity (W) Power Input (W) Rated Input (W) 1000 1060 Rated Current (A) 5.75 Air Flow Volume (m Dehumidifying Volume (l/h) EER / C.O.P (W/W) 3.21/3.61 Energy Class...
  • Page 48 Model of Outdoor Unit HRH-S071NBE Product Code CA136W0110 Compressor Manufacturer/trademark QINGAN Compressor Model YZG-A082Y2 Compressor Type ROTARY L.R.A. (A) Compressor RLA(A) 3.35 ( at 220V ) Compressor Power Input(W) 705 ( at 220V ) Overload Protector B135-140-241E Throttling Method Capillary Capacitor Starting Method Working Temp Range ( ℃...
  • Page 49 Model HSH-S091NBE COOLING HEATING Function Rated Voltage 220-240V ~ (230V) Rated Frequency 50Hz Total Capacity (W/Btu/h) 2638(W)/9000(Btu/h) 2814(W)/9600 (Btu/h) Power Input (W) Rated Input (W) 1000 1120 Rated Current (A) Air Flow Volume (m Dehumidifying Volume (l/h) EER / C.O.P (W/W) 3.21/3.61 Energy Class Fan Motor Speed (r/min) (SH/H/M/L)
  • Page 50 Model of Outdoor Unit HRH-S091NBE Product Code CA136W0121 Compressor Manufacturer/trademark PANASONIC Compressor Model 5PS102EAA22 Compressor Type ROTARY L.R.A. (A) 20.9 Compressor RLA(A) 3.85/3.60 Compressor Power Input(W) 835/850 Overload Protector B160-150-241H Throttling Method Capillary Starting Method Capacitor Working Temp Range ( º C) -7-43 Condenser Aluminum fin-copper tube...
  • Page 51 HSH-S121NBE Model COOLING HEATING Function Rated Voltage 220-240V~ Rated Frequency 50Hz Total Capacity (W) 11000(Btu/h) 12000 (Btu/h) Power Input (W) 1004 Rated Input (W) 1450 1400 Rated Current (A) Air Flow Volume (m Dehumidifying Volume (l/h) EER / C.O.P (W/W) 3.21/3.61 Energy Class Fan Motor Speed (r/min) (SH/H/M/L)
  • Page 52 Model of Outdoor Unit HRH-S121NBE Product Code CA171W0100 Compressor Manufacturer/trademark LANDA Compressor Model QXA-B120C150 Compressor Type Rotary L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) 1020 Overload Protector Throttling Method Capillary Capacitor Starting Method Working Temp Range ( ℃ ) -7-43 Condenser Aluminum fin-copper tube Pipe Diameter (mm)
  • Page 53 Model HSH-S181NBE COOLING HEATING Function Rated Voltage 220-240V~ Rated Frequency 50HZ Total Capacity (W) 4700 4900 Power Input (W) 1460 1430 Rated Input (W) 1980 1980 Rated Current (A) Air Flow Volume (m Dehumidifying Volume (l/h) EER / C.O.P (W/W) 3.21 3.43 Energy Class...
  • Page 54 Model of Outdoor Unit HRH-S181NBE Product Code CA136W0010 Compressor Manufacturer/trademark Hitachi Compressor Model ASL180SV-C7LU Compressor Type Rotary L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) 1500 Overload Protector Internal Throttling Method Capillary Capacitor Starting Method Working Temp Range ( ℃ ) -7-43 Condenser Aluminum fin-copper tube...
  • Page 55 Part name Part name Air in Indoor Unit Air out Power cord The pattern in displayer Remote controller Cool Front panel Wireless Heat remote controller Filter Guide louver Set temp. Wall pipe Bind tape Air in Connection wire Drainage pipe Outdoor Unit Air out Please refer to the actual product in case that the photo and the actual product is different.
  • Page 56 Outline and installation dimension Outline and installation dimension Outline and installation dimensions of indoor unit Take panel A for example: Air inlet Tube exit Rear View Ceiling Left Right Wall-Mounting Plate W(mm) H(mm) D(mm) 7K/9K 170(177)
  • Page 57 Outline and installation dimensions of outdoor unit Unit:mm Over 600mm Bolt Wrench M O D L E 0 7 K 7 2 0 4 3 0 3 1 0 3 1 0 2 8 6 2 5 5 09K/ 1 2 K 7 9 8 5 4 0 3 2 0...
  • Page 58 4. Electrical circuit diagram HSH-S071NBE OUTDOORUNIT INDOOR UNIT These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit.
  • Page 59 HSH-S091NBE INDOOR UNIT OUTDOORUNIT These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit.
  • Page 60 HSH-S121NBE OUTDOORUNIT INDOOR UNIT These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit.
  • Page 61 HSH-S181NBE OUTDOORUNIT INDOOR UNIT These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit.
  • Page 62 PCB function manual and operation method 6 6 6 6 6 PCB function manual and operation method Manual of functions of controller 1 Temperature Parameters Indoor setting temperature (T preset Indoor ambient temperature ( T amb. 2 Busic Functions of System Once energized, the compressor should in no way be restarted unless after at least 3-minute time interval.
  • Page 63 Overcurrent protection When the system's current is inspected to be more than 22A for continuous 3 seconds, the main unit will enter into the status as such that only the fan is running. After 3 minutes, if the overcurrent is eliminated, the complete unit will resume its original running status.
  • Page 64: Other Control

    Stop heating preset Original running status preset Start heating min. min. min. Compressor Outdoor fan setting fan speed settingfan speed min. Indoor fan min. Reversing valve Stop Defrosting Conditions and Process Intelligent defrosting is adopted, and it can conduct defrosting automatically according to the frosting condition. Double 8 displays H1.
  • Page 65 Timer changing: If the system is under timer state, the unit can be turned on/off by ON/OFF button on remote controller. Timer can be reset and the system will run according to the final setting. If timer ON and timer OFF are set at the same time under running status of the system, the system will keep the current running status. When timer OFF reaches, the system will be stopped.
  • Page 66 (0 degree) (9) Display Running icon and mode display After the unit is powered on, all the icons will be displayed once. The operation indicator icon is red during the standby state. When turning on the unit by remote controller, the operation indicator icon will be displayed, and at the same time, the icon of setting running mode will be displayed ( the mode indicator shows cooling, heating, and dehumidifying).
  • Page 67 Explosive view and spare parts list Explosive view and spare parts list Exploded View of Components and Parts of Indoor unit...
  • Page 68 PartCode Des cription HSH-S071NBE cold plasma Product Code CA136N0111 Front Panel As s y 20012432 Filter Sub-As s y 11122095 Screw Cover 24252016 Front Cas e 20012396 Axile Bus h 10542008 Guide Louver 10512162 Air Louver 2 10512114 Helicoid tongue 26112202 Dis play Board 30565062...
  • Page 69 Exploded View of Components and Parts of Indoor unit...
  • Page 70 Exploded View of Components and Parts of Indoor unit...
  • Page 71 Product Code Des cription HSH-S091NBE Product C ode C A136N0120 Rear Cas e as s y 22202135 Motor Pres s Plate 26112201 Ring of Bearing 26152022 Cros s Flow Fan 10352034 Helicoid tongue 26112202 Axile Bus h 10542704 Crank 10582070 Step Motor 1521210801 Drainage hos e...
  • Page 72 Exploded View of Components and Parts of Indoor unit...
  • Page 73 Exploded View of Components and Parts of Indoor unit...
  • Page 74 Exploded View of Components and Parts of Indoor unit...
  • Page 75 Exploded View of Components and Parts of Indoor unit...
  • Page 76 PartCode Description HSH-S121NBE Product Code CA136N0170 Wall Mounting Frame 01252015 Rear Case assy 2220210101 Axile Bush 10542704 Crank 10582070 Cross Flow Fan 10352018 O-Gasket sub-assy of Bearing 76512051 O-Gasket of Cross Fan Bearing 76512203 Ring of Bearing 26152022 Helicoid tongue 26112162 Air Louver 2 10512114...
  • Page 77 Exploded View of Components and Parts of Indoor unit...
  • Page 78 Exploded View of Components and Parts of Indoor unit 7.10...
  • Page 79 Exploded View of Components and Parts of Indoor unit 7.11...
  • Page 80 Exploded View of Components and Parts of Indoor unit 7.12...
  • Page 81 Exploded View of Components and Parts of Indoor unit 7.13...
  • Page 82 PartCode Description HSH-S181NBE Product Code CA136N0010 Front Panel Assy 20012341 Front panel A3 20012340S Filter Sub-Assy 1112208901 Front Case Sub-Assy 20012299 Front Case 20012282 Screw Cover 24252016 Display Board 30565062 Evaporator Assy 01002590 Cross Flow Fan 10352019 O-Gasket sub-assy of Bearing 76512051 Ring of Bearing 26152022...
  • Page 83 Exploded View of Components and Parts of Indoor unit 7.14...
  • Page 84 Exploded View of Components and Parts of Indoor unit 7.15...
  • Page 85 Exploded View of Components and Parts of Indoor unit 7.16...
  • Page 86 Exploded View of Components and Parts of Indoor unit 7.17...
  • Page 87 Exploded View of Components and Parts of Indoor unit 7.18...
  • Page 88 Exploded View of Components and Parts of Indoor unit 7.19...
  • Page 89 Exploded View of Components and Parts of Outdoor unit 7.31...
  • Page 90 Part Code Description HRH-S071NBE Product Code CA136W0110 Small Handle 26233100 Front Grill 22263002 Front Panel 01533255P Axial Flow Fan 10333002 Fan Motor 15013156 Motor Support Sub-Assy 01703022 Chassis Sub-assy 01203783P Clapboard Sub-Assy 01233107 Compressor and fittings 00101076 4-way Valve Accessary 43000400 4-way Valve Assy 03123281...
  • Page 91 Exploded View of Components and Parts of Outdoor unit 7.32...
  • Page 92 PartCode Description HRH-S121NBE HRH-S091NBE Product Code CA136W0121 CA171W0100 Front grill 22413431 22413431 FrontPanel 01533027P 01533027P Small Handle 26233100 26233100 Chassis Sub-assy 01203799P 01203767P Clapboard Sub-Assy 01233066 01233066 Axial Flow Fan 10333004 10333004 Fan Motor 150130671 150130676 Condenser Assy 0111347201 01113449 Motor Support 01703058 01703058...
  • Page 93 Exploded View of Components and Parts of Outdoor unit 7.33...
  • Page 94 PartCode Description HRH-S181NBE Product Code CA136W0010 Front grill 22413431 Axial Flow Fan 10333004 Front Panel 015330124 Chassis Sub-assy 012032134 4-way Valve Assy 03123303 Magnet Coil 43000400 Capillary Sub-Assy 03103911 Compressor and fittings 00120023 Big Handle 26233433 Valve 07100004 Valve 07100006 Valve Support 01713041 Right Side Plate Assy...
  • Page 95 Exploded View of Components and Parts of Outdoor unit 7.34...
  • Page 96 Trouble-Shooting Trouble-Shooting...
  • Page 99 Locked-rotor protection H6 of PG motor: Possible reasons: 1. The fan speed is too low due to tuyere blockage; 2. Fan blade get stuck; 3. Motor get stuck; 4. The motor capacitor is damaged; 5. Motor damage (foreign odor, open winding circuit or short winding circuit are all abnormal conditions, and when measuring the winding resistance, note if the temperature of the motor casing is too high causing thermal protection action);...
  • Page 100 HSH-S241/301/361NBE CONTENTS Product Specificiation……………………..1 Refrigeration Diagram……………………..5 Introductions of Installation………………..8 Remote Controller Introductions…………14 Brief Introduction for Usage………………23 Wiring Diagram…………………………….32 Disassembly & Assembly…………………42 Troubleshooting Guide……………………50 Exploded Views & Parts List……………...69 Appendix Data Sheet………………………………….76 Operation Details…………………………..79 Circuit & Wiring Diagram of PCB…………87...
  • Page 101 Chapter 1 Product Specificiation Chapter 1 Product Specificiation Chapter 1 Product Specificiation 1.1 Photo of Product 1.1 Photo of Product...
  • Page 102 Outdoor Unit For 24K...
  • Page 103 Outdoor Unit For 30/36K...
  • Page 104: Outline Dimensions

    1.2 Outline Dimensions Indoor Unit MODEL 24000BTU 1095 MODEL 30000BTU 36000BTU 1185 1310 Outdoor Unit MODEL 24000BTU MODEL 30000BTU 36000BTU...
  • Page 105: Cooling Only

    Chapter 2 Refrigeration Diagrams 2.1 Cooling Only Cooling Mode Cooling Cycle Steam-gas of low pressure Indoor heat exchanger Compressor (Evaporation) (Compression) Liquid of low pressure Gas of high pressure (also a little gas) & temperature Super cooled liquid of high pressure Capillary Outdoor heat exchanger (Throttling)
  • Page 106 2.2 Cooling & Heating Cooling Mode Cooling Cycle Steam-gas of low pressure Indoor heat exchanger Compressor (Evaporation) (Compression) 4-way valve Liquid of low pressure (Heat pump only) (also a little gas) Gas of high pressure & Super cooled liquid temperature of high pressure Capillary Outdoor heat exchanger...
  • Page 107: Heating Mode

    Heating Mode Heating Cycle Gas of high Pressure & temperature Indoor heat exchanger Compressor (Condensation) (Compression) 4-way valve (Heat pump only) Super cooled iquid of low pressure Steam-gas of low pressure Super cooled liquid of high pressure Capillary Outdoor heat exchanger (Throttling) (Evaporation)
  • Page 108 Chapter 3 Instructions of Installation Outdoor Unit Size of Shape (mm) 600X250X490 760X260X540 800X300X690(590) The distance between indoor and outdoor unit should be 5 meters and pipe length can 900X330X860 go up to maximum 15 meters with additional refrigerant charge. Max.
  • Page 109 First make changes to wall and make sure that is hard and secure. Using four type screws to fasten the installation board onto the wall. Keep it water lever horizontal direction and perpendicular in vertical direction. Otherwise it might cause water drops when air-conditioner is running cooling operation.
  • Page 112 Unscrew the screw, take off the control panel cover from the unit. Connect the cable to their terminals according to their number. The grounded wire connection: 1.loosen the grounded screw of electrical shelf. 2.Connect the grounded wire with the grounded screw then setscrew in the mark formerly.
  • Page 113 Make sure whether the outlet air temperature subtract from inlet sgives more than 10...
  • Page 114 HEALTH SLEEP FEELING POWER TIMER/CLOCK...
  • Page 115: The Closing State Of Remote Controller

    The closing state of remote controller: Mode display Auto Cool Dry Heat Wet Emission display Fan speed display Humidity display Anion function display Temperature display Power display Feeling display Swing 2 display Sleep display Swing display Timer/Clock display Timer On/Off display...
  • Page 116 button This button can set room temperature. Press it once ,the temperature increases 1 .Press it continu- ously, the temperature increases at the speed of 4 This function is invalid when the appliance at the Fan and Auto mode. SWING button Press the button, the LCD shows the symbol, the...
  • Page 117 The opening state of remote controller: HEALTH SLEEP SWING 2 FEELING DISPLAY TIMER/CLOCK...
  • Page 118 HEALTH button Press this button ,the LCD shows the symbol, the anion emission function of the air conditioner is started. Press the button once again, The symbol disappears, the function is cancelled at the same time. button This button not only can adjust clock time and the timer time but also can set room humidity.
  • Page 119 button SLEEP button Press this button ,the LCD shows the symbol, the sleeping function of the air conditioner is started. After 7 hours of setting this function ,the air conditioner will beoff automatically. Press the button once again, The symbol disappears, the function is cancelled at the same time.
  • Page 120 3.Press the button, you can set the temperature range from 16 to 32 4.Press the FAN button, you can select fan speed from High Auto 2.Press the button, you can set the temperature range from 16 to 32 3.Press the FAN button, you can select fan speed.
  • Page 121 2.Press the FAN button, you can select fan speed . 2.Press the FAN button, you can select fan speed . 1.Press the TIMER/CLOCK button for 5 seconds, the time indicator at present begins to glimmer. 2.Adjust present time through pressing the button.
  • Page 122 1.Press the TIMER/CLOCK button ,the remote controller display immediately. 2.Adjust time through pressing the button. 3.Press the TIMER/CLOCK button again, the Timer OFF setting is finished. The waste battery should be disposed properly.
  • Page 123: Parts Description

    Chapter 5 Brief Introduction for Usage Parts Description Indoor Unit Indoor Unit Installation board Middle frame Indication light and signal receiver Front panel Horizontal airflow direction vane Vertical airflow direction vane(inner) Air filter Pipe protection ring Drain pipe Outdoor Unit Outdoor Unit Pipe and Drain pipe Cut-off valve...
  • Page 124 Usage Working condition Maximum: DB/WB 32 /23 Indoor DB/WB 21 /15 Minimum: Cooling Maximum: 43 /26 DB/WB Outdoor 21 /15 DB/WB Minimum: Maximum: 27 - DB/WB Indoor 20 - DB/WB Minimum: Heating Maximum: 24 /18 DB/WB Outdoor -5 /-6 DB/WB Minimum: Remote control usage Air-conditioner Remote Control Instruction...
  • Page 125: Items Of Attention

    Air flow direction adjusting 1.Horizontal air flow direction adjusting Move the vane and change the horizontal wind direction with hands. Note: Adjust the horizontal air flow direction before the air-conditioner starts. Do not put reach your finger into air-out window when the air-conditioner is operating. 2.Vertical air flow direction adjusting...
  • Page 126 Optimal operation Pay attention to the following items so as to ensure optimal operation of the system, details of operation see the relevant content. Please set the scheduled operation time with the remote control. Set the suitable temperature for a comfortable environment. Do not make the room too cold or too hot.
  • Page 127 Danger Do not put your hands or stick-shaped objects Do not touch the swinging wind vanes, into the air outlet of the indoor and outdoor or it may clamp your finger and damage the driving parts of the wind vanes. unit, otherwise, the rotating fan at high speed may cause injury to you.
  • Page 128 In the following situations, please handle it according to the following methods, if it does not work, please contact service centre and inform the failure details Causes Methods of resolution Failure Power supply failure Wait for the recovery of power supply The power switch is released Switch on the power Start-up...
  • Page 129 2.White steam comes out from the indoor unit During the cooling operation , under high relative humidity indoors, white steam may come out due to the high humidity and temperature difference of air inlet and outlet. The air-conditioner converts to heating operation after the frost dissolving, the moisture due to frost dissolving is discharged in form of steam.
  • Page 130 Cleaning Warning: For safety purposes, please turn off the air-conditioner and cut off the power supply before cleaning. Cleaning the indoor unit 1.Wipe the indoor unit with dry cloth . 2.If the indoor unit is very dirty, please wipe with wet cloth dipped by cold water. 3.The panel of indoor machine may be taken off.
  • Page 131 Installation The installation must be carried out by a licensed and qualified technician only. Guide of customer The customer should have a qualified power supply coincident with the tag of the air conditioner, its voltage should be in the range of 90-110% of its rated voltage. The power supply circuit should have leakage protector and air switch of which the capacity should be more than 1.5 times of the maximum current.
  • Page 132 6.3 Electric chart for 24K(Non inverter) Indoor unit Frost Eliminatin Transformer Plug Indication Receiver Fan Motor Step Motor panel panel Force Switch Controlling Panel Temperature Sensor To Outdoor Unit To Power Indoor Unit Electric Chart...
  • Page 133 Outdoor unit Intelligent Defrost Unit have no Temperature Sensor...
  • Page 134 6.4 Electric chart for 30K(Non inverter) Indoor unit Receiver panel Indication panel Transformer Fan Motor Controlling Panel Force Switch VALVE COMP WFAN Anion Brown Blue Brown Black Blue Yellow/ generator Green To Outdoor Temperature Unit Sensor To Outdoor Unit 1886R004966 Indoor Unit Electric Chart...
  • Page 135 Outdoor unit Fan Motor White Fan Motor Capacitor Orientation Valve Black Blue Blue Brown Temperature Sensor Compressor C Yellow Black Compressor Capacitor Black Blue Brown Brown Blue Red Black Purple Yellow/ 2(N) Green Brown Blue Brown Blue Black Yellow/Green Brown Blue To Indoor Unit 1886R003401 To Power...
  • Page 136 6.5 Electric chart for 36K(Non inverter) Indoor unit Receiver panel Step Motor Indication panel Transformer Fan Motor Controlling Panel Force Switch VALVE COMP WFAN N(2) Temperature To Outdoor Sensor Unit To Outdoor Unit 1886R010848 Indoor Unit Electric Chart...
  • Page 137 Outdoor unit Compressor Brown Contactor Brown Yellow Compressor Capacitor Blue Blue Compressor Black Temperature Sensor Brown Brown Black Blue Black 1 N(2) Yellow/ Green White Black Yellow/ Brown Blue Blue Blue Green To Indoor Unit To Indoor Unit Fan Motor Fan Motor Orientation Valve 1886R010845...
  • Page 138 (2)Indoor unite and outdoor unit of 000BTU~36000BTU Attention: Turn off the air-conditioner and pull out the plug of the power supply before e service. 1. Ind unit: Part Operation Process Remark Front ) Turn off the air-conditioner and cut panel off the power supply;...
  • Page 139 Electrical 1) Do No. “1” firstly; component 2) Pull out all tie-in connecting with PCB and the temperature sensor, etc.; 3) Screws off the screws and bolts at the three positions indicated in the picture. Untie outdoor unit’s interconnection cord and power supply cord from the terminal of the electrical box.
  • Page 140 2. Outdoor unit Part Operation Process Remark General 1) Screw off one fastening bolt from the operation electrical box cover, and offload the box cover; 2) Pull out the connecting cord from the electrical box; 3) Screw off the five fastening bolts from the cover board, and offload the cover board;...
  • Page 141 Compressor 1) Do “1” ,“2”, “3” firstly; 2) Open the cover of the compressor, and loosen the connecting cables; 3) Weld off the inlet and outlet tubes of the compressor; 4) Screw off three flat nuts; 5) Offload the compressor;...
  • Page 142: Error Code

    Chapter 8 Troubleshooting Guide 8.1 Error Code Error Code Problem Temperature sensor of air intake fault Temperature sensor of outdoor coil fault Temperature sensor of indoor coil fault PG motor of indoor unit feedback fault...
  • Page 143 8.3 Troubleshooting Guide for -36K 1. The Foremost Inspecting Items ⑴The input voltage must be within +10% tolerance of the rated Voltage. If it is not the case, the air-conditioner will probably not work normally. ⑵Check the connecting cord between indoor unit and outdoor unit to see if it is properly connected.
  • Page 144 dehumidifying mode, and the indoor exchanger from being frozen. fan motor slows down.
  • Page 145 2. No Power Display ⑴Items ①Check if the input voltage is correct? ②Check if the AC power supply connecting is correct? ③Check if the output voltage of the manostat L7805(IC2)is correct? ⑵Trouble shooting procedure...
  • Page 146 3. The Indoor Fan Motor Does Not Work ⑴Items ①Check if the indoor fan motor is connected correctly to the connector(CN8)? ②Check if the AC input voltage is correct? ③ Check if the IC of indoor fan motor is connected correctly to the connector(CN2)? ④Check if the capacity of indoor fan motor is connected correctly to the connector(CN8)?
  • Page 147 4. The Outdoor Unit Does Not Work ⑴Items ①Check if the input voltage is correct? ②Check if the wire connection of the outdoor connecting terminal is correct? ⑵Trouble shooting procedure...
  • Page 148 5. The Step Motor Does Not Work ⑴Items ①Check if the input voltage is correct? ②Check if the step motor controlling the up-down movement firmly connected to Cn2? ⑵Trouble shooting procedure...
  • Page 149 6. Heating Mode Can Work, But No Hot Air Blow ⑴Check if the set temperature is lower than the indoor temperature? ⑵Check if the indoor PCB is connected to the terminal correctly?
  • Page 150 8. The Failure Analysis of the Main Parts...
  • Page 151 (3) Indoor unit exploded picture (24-36 BTU, S Series)
  • Page 152 INDOOR UNIT LIST Name Name Quantity 中框 Medium frame 导风架 Air-vent holder 导风门 Horizontal air-blade 导风叶片 Vertical air-blade 蒸发器支架 Left plastic-crutch for evaporator 贯流风叶 Through-flow fan 底座盖板 Cover of chassis 底座 Chassis 挂板 Mounting plate 管路压攀 Pipe clamp 滑块 Slip block 塑封电机...
  • Page 153 (4) Outdoor unit exploded picture ( -36K BTU,S Series)
  • Page 154 OUTDOOR UNIT LIST Name Name Quantity 顶盖板 Top cover board 轴流风叶 Axial-flow fan 风机电机 Fan motor 电机电容 Motor capacitor 电机架 Motor bracket 冷凝器组件 Condenser assembly 防护网罩 Defense net 挖手 Handle 右侧板 Right side plate 毛细管管路组件 Capillary assembly 电容抱攀 Capacitor clamp 端子板...
  • Page 155 The basic condition of electrical control using 1、the suitable scope of electricity and voltage: input voltage 175V~253V; 2、alternating current input voltage frequency: 50Hz; 3、environment temperature of electronic control working: (-10~+70)℃; 4、environment humidity of electronic control working: RH20%~RH90%; 5、indoor fan for the PG plastic motor , three-pulse feedback signal;...
  • Page 156 normal working electricity less than 1.5A; 7、the four-way valve working electricity less than 1A/220V; 8、the swing motor is DC12V, four-phase eight clap step motor ; 9、the compressor is single power, the normal working electricity less than 1.5A; partition of electrical control’s function controller’s function constitute by some parts below: 1、...
  • Page 157 13、self-test function Main function instruction 1、 、 、 、 proper noun and expression TA: indoor environment temperature TE: indoor evaporator temperature TS: setting temperature 2、 、 、 、 mandatory switch when the air conditioner under the opening condition, press this button is closing phenomenon;...
  • Page 158 4、 、 、 、 cooling mode setting the temperature by remote controller, the control scope of temperature is 16℃~32℃, press the “up”、 “down” button can adjust the temperature. Press the “wind speed choose” button can choose the automatic wind、high speed wind、middle speed wind、low speed wind. Under this mode ,the four-way valve closed.
  • Page 159 when the heating mode normal operation, the compressor start、 outdoor fan operation、valve circuit have power、indoor fan open, and when satisfy the condition in the same time, the electric heating open. 9、 、 、 、 intelligent defrost function When this mode operation , the conditioner begin to defrost if satisfy the condition, the sleeping light flicker.
  • Page 160 choose button or close, the sleeping cancel, finish the sleeping operation. Cooling operation sleeping: Setting temperature rise1℃ again rise1℃ original setting temperature 7h (sleep finish, close) Heating operation sleeping: : : : Setting temperature original setting temperature drop2℃ drop2℃ again 7h(sleep finish,close)...
  • Page 161 setting time, the conditioner automatic close. ③ Setting the “on” timer time Just setting under condition of the air conditioner closed, the timing scope is 1min~12h, divide 12h a.m. and 12h p.m., when arriver the setting time, the conditioner automatic open. Open or close the conditioner after setting timing, the intrinsic timing and sleeping automatic cancel.
  • Page 162 electricity protect 6times or 8s Note: the nixie tube just display homologous fault code, if not have the nixie tube and just have the timing light, so the timing light point homologous fault code. When the indoor fan motor add the voltage, if not detection pulse signal which feedback by the indoor fan motor, close the output voltage of power supply to the indoor fan motor on the remote controller , after standby 30s, offer the voltage to the indoor fan motor again, if also not...
  • Page 163 App3 Current & Wiring Diagram of PCB (Non Inverter)
  • Page 168: Delux Series

    DELUX SERIES...
  • Page 169 Hyundai HSH-D071/091/121NBE Normal panel Mirror panel...
  • Page 170 D-121NBE D-091NBE D-091NBE D-121NBE...
  • Page 171 Note: only 09/12 outdoor fan is explained as example for outdoor fan...
  • Page 173 above 7cm above 7cm above 20cm...
  • Page 175 HSH D-091/121NBE...
  • Page 176 6 PCB function manual and operation method 6.1 Controller Function Manual 1 This function manual is applicable to 9K and 12K model. Temperatures in this function manual are written in unit of centi degree. In case of degree Fahrenheit, conversion equation for the two is: x1.8+32.
  • Page 177 (2) DRY mode ① The condition and process of dehumidifying If T >T +2℃, DRY mode will act. The compressor and the outdoor fan will run, and indoor fan will run at low speed. ≤T If T -2℃≤T +2℃, DRY mode will act. The indoor fan will run at low speed. The compressor and outdoor fan stop six minutes after it is started, and restart four minutes later.
  • Page 178 Cooling runs +2℃ Dehumidifying runs -2℃ Stop running 6 minutes Compressor 4 minutes Outdoor fan Indoor fan Low fan speed Stop ② Protection function ◆ Antifreezing protection In cooling by dehumidifying mode, when the antifreezing protection is detected, the compressor and the outdoor fan will stop running, and the indoor fan will keep running at low speed.
  • Page 179 Noise protection When “run/stop” is used to shut down the machine, the four-way valve delays two minutes to stop, or delay two minutes when converting mode. (4) FAN mode In FAN mode, the compressor and the outdoor fan will stop running, and the indoor fan will run at the set speed.
  • Page 180 3 Other control (1) Power-off memory function: Memory contents: mode, up and down purge, light, set temperature, set fan speed, ordinary timing (moment timing without memory), Fahrenheit/Centigrade. After power off, supply power again to enable automatic starting up according to memory contents.
  • Page 181 shut down when pressing the key again. (4) Buzzer When controller is powered on and detects that key is pressed or signal from remote control is received, the buzzer gives a warning sound. (5) Sleep control Sleep function is set in COOL or DRY mode. After one hour, T rises by 1℃;...
  • Page 182 (6) Strong function Strong functions may be set in COOL and HEAT mode. (7) Dry function Dry function may be set in COOL mode and DRY mode. (8) Automatic wind speed control In this mode, the indoor fan automatically selects high, medium and low wind speed according to ambient temperature change.
  • Page 183 6.2 Controller Function Manual 2 This function manual is applicable to 18K and 24K model. Temperatures in this function manual are written in unit of centi degree. In case of degree Fahrenheit, conversion equation for the two is: x1.8+32. ℃ 1 Temperature parameters ◆...
  • Page 184 When it is detected that the system current exceeds 22A for three consecutive seconds, the main unit enters a running state in which only fan runs. If overcurrent is eliminated 3 minutes later, the whole unit will resume running in the original state. If six times of overcurrent protection occur consecutively (when compressor keeps running for more that six minutes, time of protection is cleared), the whole unit stops and enters a running state in which only fan runs.
  • Page 185 ① The condition and process of dehumidifying If T >T +2℃, DRY mode will act. The compressor and the outdoor fan will run, and indoor fan will run at low speed. ≤T If T -2℃≤T +2℃, DRY mode will act. The indoor fan will run at low speed. The compressor and outdoor fan stop six minutes after it is started, and restart four minutes later.
  • Page 186 +4℃ +2℃ ②The condition and process of defrosting Intelligent defrosting is used. Frost is removed automatically according to frosting conditions. Double 8 displays H1. ③Protection function Anti-high-temperature protection...
  • Page 187 When evaporator tube temperature is detected too high, the outdoor fan will stop running; when the temperature returns to normal, the outdoor fan will resume running. Noise protection When “run/stop” is used to shut down the machine or convert mode, the reversal valve delays two minutes to stop.
  • Page 188 system keep stop state. When set time for timed startup is reached, the system starts to run. After set time for timed startup is reached every day, the system runs in pre-set mode. When set time for timed shutdown is reached, the system stops working. When set time for timed startup and shutdown is same, the shutdown command is implemented.
  • Page 189 1 hour 2 hours Above 2 hours Set temperature T (5) Strong function Strong functions may be set in COOL and HEAT mode. (6) Drying function Drying function may be set in COOL and DRY mode. (7) Automatic wind speed control In this mode, the indoor fan automatically selects high, medium and low wind speed according to ambient temperature change.
  • Page 190 ② Double 8 display When the air conditioner is firstly turned on and started, the nixietube displays the current set temperature in a default manner (the set temperature range is 16-30℃). When receiving the displayed and set temperature signal, the nixietube displays the set temperature; when receiving the displayed signal of ambient temperature, the nixietube displays the current ambient temperature of the room.
  • Page 217 D091NBE...
  • Page 219 D121NBE...
  • Page 224: Prestige Series

    PRESTIGE SERIES...
  • Page 225 HSH-P091/121NDC Type of contents 1. OPERATION RANGE 2. SPECIFICATION 3. INSTALLATION 4. ELECTRICAL DATA 5. CONTROL MODE 6. TROUBLE SHOOTING 7. CHECKING COMPONENTS 8. PART LIST AND EXPLODE VIEW...
  • Page 226 2-1. Unit specifications Model No. HSH-P091NDC Type T1, H/P, INVERTER Ratings Cooling Capacity 2600(1200-3000) Heating Capacity 2900(1200-3500) Rated Input-Cooling 810(300-1450) Rated Input-Heating 803(300-1500) Moisture Removal L/H.r Air Circulation m3/h EER for Cooling 3.21 COP for Heating 3.61 Energy Class Cooling Energy Class Heatling Refrigerant R410A...
  • Page 227 Sleep Operation Smart Function Dimmer Y Super Function Compressor Indicator Auto Restart Other Net Di mensions Indoor Unit 750×250×190 WxHxD (mm) Outdoor Unit 715×482×240 Indoor Unit Net Weight (Kg ) Outdoor Unit Packing D imensions W xHxD Indoor Unit 800×325×245 (mm) Outdoor Unit 830×530×315...
  • Page 228 2-2-2 OUTDOOR FAN MOTOR ELECTRIC PERFORMANCE PARAMETER Motor model DG13Z1-39 Rated power source 208~240V 50Hz Fan capacitor 1.5μF/450V Poles --- Rated load output(W) Ambient temperature(℃) -5 ℃~+43℃. 2-2-3. COMPRESSOR ELECTRIC PERFORMANCE PARAMETER Compressor model 39A23VPM&5JKE Compressor type Rotary Motor type. Direct current brushless motor Motor Starting type...
  • Page 229 1、How to choose an air conditioner: a. Choice for reference: 150-170W/㎡ for average rooms; b. Choice for reference: 160-200W/㎡ for small size offices; c. Choice for reference: 220-350W/㎡ for restaurants; d. Choice for reference: 200-300W/㎡ for entertaining venues; e. Choice for reference: 220-280W/㎡ for the top floor. Note:1W = 3.412btu.
  • Page 230 5-3. Control function 5-3-1 Emergency switch 5-3-1-1 Press the emergency switch once to turn on the machine and press it again to turn off the machine; in the automatic mode, the indoor control temperature is set at 24℃ with the indoor fan speed setting is automatic and the flaps sweep.
  • Page 231 5-3-3-2 Timer off: When set to stop in a set time by the remote controller, the air conditioner will start in the timer off condition. When the set time is up, the air conditioner will turn off after receiving a signal from the remote controller. If the air conditioner has not received a signal from the remote controller when the set time is up, it will turn off automatically.
  • Page 232 c. When T – T <-3℃, it starts in the heating mode. room After the first run in the cooling or heating mode, the mode will be changed as the following: a. When T – T >3℃, it will be changed to the cooling mode; room b.
  • Page 233 and it is not available when it is subject to the sensor on the remote controller. 5-3-7-2 Outdoor Fan The outdoor fan’s speeds are divided into two levels which can be changed over according to outdoor ambient temperatures. When operating at a fixed frequency, the outdoor fan is forced to operate at the high speed. 5-3-7-3 Indoor fan When the fan speed is set at the high, medium and low fan speeds, the fan runs at a preset speed.
  • Page 234 Indoor Fan Speed room ≤2 room C <T <4 Medium room ≥4 High room 5-3-8-3 Cold air prevention In the heating-run, to prevent the indoor fan from blowing cold air, the indoor fan speed is different from the set speed after turning on air-conditioner. 5-3-8-4 Residual heat blowing off When the compressor is turned off in the heating run, the indoor fan does not stop at once, but until the indoor evaporator temperature is below 23...
  • Page 235 Dehumidifying area I: Operation at the frequency in the range (30–80 Hz) according to ∆t indoor ambient ∆t(℃) f(Hz) ≥2 Efficient Dehumidifying area II: The compressor stops for 5 minutes and operators for 5 minutes at the lowest frequency. Dehumidifying area III: The compressor stops. 5-3-10 Air Blowing mode The outdoor unit does not work while the indoor fan runs with the fan speed selectable at the auto, low, medium and high speeds.
  • Page 236 × Frequency descent or restriction on frequency ascent ★ ★ caused by anti-freeze in cooling or overload control in heating × Frequency descent or restriction on frequency ascent ★ ★ caused by too high compressor discharge temperature × × Restriction on maximum operation operating frequency ★...
  • Page 237 6-1. Trouble alarm Trouble List 6-1-1 Indication on the outdoor unit When the compressor is interrupted, the outdoor LEDs are used to indicate the troubles listed below: Ο: flashing ×: OFF Symbols for indicator lights: ★: ON LED1 LED2 LED3 Troubles ×...
  • Page 238 Communication trouble Indoor coil temperature sensor in trouble Current overload control Communication between the indoor and outdoor in trouble Maximum current control Indoor fan motor operation abnormal Communication trouble(between Grid protection alarm (cabinet type) outdoor unit and driver unit) Outdoor EEPROM in trouble Detecting failures by zero-crossing Compressor exhaust temperature too high control...
  • Page 239: Service Flow Chart

    7-2. Service flow chart Switch on the power supply Does it receive the Start up self-test remote controller Does DLED screen function signal? display normally? Check the result remote fuse(F01, controller in good 3.15A/250V) blown? Replace the battery press condition ACL button.
  • Page 240 Error code 33 Take from Indoor temperature ,Measure sensor resistance of thermistor Does the resistance of thermistor have Replace characteristics indoor pcb board on part 6-3 Error code 34 Take from Indoor Coil sensor ,Meaure trouble resistance of thermistor Replace Does the unit exit hot thermistor protector...
  • Page 241 Error code 39 Indoor fan motor trouble Set the air conditioner operate in fan mode Check the connector of Does fan motor stop with the Is indoor fan motor running? indoor motor remote controller Does the socket CN1(1-3) of Indoor control board faulty indoor control board and replace it have power input...
  • Page 242 Error code 36 Communication trouble Connect the indoor and Are all the lead wires connected outdoor unit again according between indoor and outdoor unit? Display board fault, to the wiring diagram replace it Is there power output between indoor T/B 1 and 2 AC220V? Indoor control Indoor control board Is the system in...
  • Page 243 7-1. Check refrigerant system TEST SYSTEM FLOW ① Conditions: Compressor is running. ② The air condition should be installed in good ventilation. Tool: Pressure Gauge ① ② ③ Technique: feel test SEE---Tube defrost. FEEL---The difference tube temperature. TEST--- Test pressure. cooling run heating run Outdoor unit...
  • Page 244 Cooling mode Test system The pressure on the pressure.Does the low high side. pressure normal at service part ? Recharge refrigerant after air purging with If the pressure is The pressure on the the vacuum close to static low side. pump.Does the low pressure? pressure nomal over...
  • Page 245 7-2.Check parts unit 1. INDOOR FAN MOTOR .MOTOR EXAMINE AND REPAIR Circuit diagram BROWN Vc c BLACK Vo ut YELLOW Test in resistance. TOOL: Multimeter. Test the resistance of the main winding. The indoor fan motor is fault if the resistance of main winding 0(short circuit)or∞(open circuit).
  • Page 246 Test in resistance. TOOL: Multimeter. Test the resistance of the main winding. The outdoor fan motor is fault if the resistance of main winding 0(short circuit)or∞(open circuit). Notes: 1) Please don’t hold motor by lead wires. 2) Please don’t plug IN/OUT the motor connector while power ON. 3) Please don’t drop .Hurl or dump motor against hard material.Malfunction may not be observed at early stage after such shock.But it may be found later,This type of mishandling void our warranty.
  • Page 247 Test in resistance. TOOL: Multimeter. Test the resistance of “LOAD” port. The filter is fault if the resistance of winding 0(short circuit)or∞(open circuit) 6. STEPPER MOTOR Test in resistance. TOOL: Multimeter. Test the resistance of winding. The stepper motor is fault if the resistance of winding 0(short circuit)or∞(open circuit).
  • Page 248 Fuse Fig.2 2. CAPACITOR Remove the lead wires from the capacitor terminals, and then place a probe on the capacitor terminals as shown in Fig.3.Observe the deflection of the pointer, setting the resistance measuring range of the multimeter to the maximum value. The capacitor is “good”...
  • Page 249 8-1. Indoor unit 1. Exploded View 2. Part list PART DRAWING NO. DESCRIPTION(CHINESE) DESCRIPTION Q'TY 1359261 G1K30/R00.01.01-00 底座部件 base parts 1339745 K33190002 挂墙板部件 installation plate assy 1276892 KT20P0-10 排水管 drainage hose 1222824 KT25F0-05 轴承座 bearing 1203627 RZA-2-2360-004-XX-0 导流板 air duct plate 1203661 RZA-2-2478-112-XX-0 卡板...
  • Page 250 1412758 G1K30/R00.02-07 卡板 baffle 1385308 G1K30/R00.02-03 接线盖 wiring distribution cover 1338256 G1C60/00.05.01-01 显示盒(VG1/VL1) display box(VG1/VL1) 1412963 G1K39/R00.05.01-01-HIPS 显示盒(VT1) display box(VT1) 1427666 K36430324 显示板(VG1/VL1) display board(VG1/VL1) 1430007 K36430326-+KGK-94G1.05-00 显示板(VT1) display board(VT1) 面板(图案)(不带商标) 1382596 G1K30/R00.02-01(ZX) front panel without LOGO(VG1) (VG1) G1K31/R00.02.01-01-90210 1364975 面板(VL1)...
  • Page 251 2. Part list PART DRAWING NO. DESCRIPTION(CHINESE) DESCRIPTION Q'TY 1405623 W1M0N/R00.02.01-00 面板部件 panel parts 1405123 DG22Z1-33 轴流风扇 propeller fan 1415216 DG13Z1-39 风扇电机 fan motor 1308210 W1E0L/R00.02-05 电机支架 motor bracket 1412666 +W1M0K/RZ01.04.01-00 冷凝器组件 condenser ASS'Y 1248091 W1E0L/R00.02-03 支撑件 mounting plate 1393359 W1E0A/Z00.04-01 后网...
  • Page 252 1276574 W1A1L/00.02-01 接线盖 wiring distribution cover assy 1380315 K1C510071 温度传感器 Temperature Sensor 1380309 K1C510070 温度传感器 Temperature Sensor 1205018 4-5259-395-01-0 温度传感器 temperature sensor 1412359 K36412645 控制板 control board 1407678 W1M0K/RZ00.05.01-01 电器盒 elec joint box 1222462 +DG17D4-05 接线端子板 terminal panel 1407674 W1M0K/RZ00.05.01-02 连接板...
  • Page 253 2-1. Unit specifications Model No. HSH-P121NDC Type T1, H/P, INVERTER Ratings Cooling Capacity 3200(1200-3500) Heating Capacity 3400(1200-4000) Rated Input-Cooling 997(300-1550) Rated Input-Heating 942(300-1600) Moisture Removal L/H.r Air Circulation EER for Cooling 3.21 COP for Heating 3.61 Energy Class Cooling Energy Class Heatling Refrigerant R410A...
  • Page 254 Sleep Operation Smart Function Dimmer Super Function Compressor Indicator Auto Restart Other Net Dimensions Indoor Unit 750×250×190 WxHxD (mm) Outdoor Unit 715×482×240 Indoor Unit Net Weight (Kg) Outdoor Unit Packing Di mensions Wx HxD Indoor Unit 800×325×245 (mm) Outdoor Unit 830×530×315 Indoor Unit Gross Weight (Kg)
  • Page 255 2-2-2 OUTDOOR FAN MOTOR ELECTRIC PERFORMANCE PARAMETER Motor model DG13Z1-39 Rated power source 208~240V 50Hz Fan capacitor 1.5μF/450V Poles --- Rated load output(W) Ambient temperature(℃) -5 ℃~+43℃. 2-2-3. COMPRESSOR ELECTRIC PERFORMANCE PARAMETER Compressor model 39A23VPM&5JKE Compressor type Rotary Motor type. Direct current brushless motor Motor Starting type...
  • Page 256 8-1. Indoor unit 1. Exploded View 2. Part list PART DRAWING NO. DESCRIPTION(CHINESE) DESCRIPTION Q'TY 1359261 G1K30/R00.01.01-00 底座部件 base parts 1339745 K33190002 挂墙板部件 installation plate assy 1276892 KT20P0-10 排水管 drainage hose 1222824 KT25F0-05 轴承座 bearing 1203627 RZA-2-2360-004-XX-0 导流板 air duct plate 1203661 RZA-2-2478-112-XX-0 卡板...
  • Page 257 1412758 G1K30/R00.02-07 卡板 baffle wiring distribution cover 1385308 G1K30/R00.02-03 接线盖 assy 1338256 G1C60/00.05.01-01 显示盒(VG1/VL1) display box(VG1/VL1) 1427666 K36430324 显示板(VG1/VL1) display board(VG1/VL1) 面板(图案)(不带商 front panel without 1382596 G1K30/R00.02-01(ZX) 标)(VG1) LOGO(VG1) G1K31/R00.02.01-01-90210 1364975 面板(VL1) art cover(VL1) 白 1356581 G2C30/R00.02-03 显示膜片(VG1) display film(VG1) 装饰板...
  • Page 258 8-2.Outdoor unit 1. Exploded View 2. Part list PART DRAWING NO. DESCRIPTION(CHINESE) DESCRIPTION 1405623 W1M0N/R00.02.01-00 面板部件 panel parts 1405123 DG22Z1-33 轴流风扇 propeller fan 1415216 DG13Z1-39 风扇电机 fan motor 1308210 W1E0L/R00.02-05 电机支架 motor bracket 1422142 W1M0K/RZ02.04.01-00 冷凝器组件 condenser ASS'Y 1248091 W1E0L/R00.02-03 支撑件...
  • Page 259 1276574 W1A1L/00.02-01 接线盖 wiring distribution cover assy 1380315 K1C510071 温度传感器 Temperature Sensor 1380309 K1C510070 温度传感器 Temperature Sensor 1205018 4-5259-395-01-0 温度传感器 temperature sensor 1412357 K36412644 控制板 control board 1407678 W1M0K/RZ00.05.01-01 电器盒 elec joint box 1222462 +DG17D4-05 接线端子板 terminal panel 1407674 W1M0K/RZ00.05.01-02 连接板...