Part 2 Functions & Controls
4.3 Air volume control
• Indoor fan motor control have 6 steps.
• Air volume is controlled "SH", "H", "Med", "Low" by the remote con-
troller.
• "LL" step is selected automatically in Hot start operation.
4.4 Natural Air Control(Auto Wind)
• When the Auto Step is selected and then operated, the high, medi-
um, or low speed of the airflow mode is operated for 2~15 sec. ran-
domly by the Chaos Simulation.
4.5 Auto Swing
• By the Chaos swing key input, the upper/lower vane automatically operates with the Chaos swing or it is fixed to
the desired direction.
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
CLOSED
Mode 8
Mode 7
65°
Mode 6
Mode 5
Mode 4
20°
Mode 3
Mode 2
8°
Mode 1
OPEN
- 14 -
Step
Discription
LL
Very low, In heating mode
L
Low
M
Med
H
High
SH
Super high
Auto
Natural wind
LGE Internal Use Only