Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
LMAN127HVT
Multi F Art Cool™ Mirror
12,000
Btu/h Indoor Unit
Performance:
Nominal Cooling Capacity (Btu/h)
Nominal Heating Capacity (Btu/h)
Cooling Nominal Test Conditions:
Indoor:
80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Electrical:
Power Supply (V¹/Hz/Ø)
Rated Amps (A)
Piping:
Liquid Line (in, OD)
Vapor Line (in, OD)
Drain OD, ID (in)
Temperature Sensor
Features:
•24‐Hour on/off mer
•Jet Cool/Jet Heat
•Auto opera on
•Plasma air purifying system
•Auto restart
•Self‐cleaning indoor coil
•Chaos Swing
•Condensate sensor connec on
•Inverter
•Group control
(variable speed fan)
Included Accessories:
•Wireless Handheld Remote Controller ‐ AKB73635606
Optional Accessories:
LG Programmable Thermostat ‐ PREMTB10U
Simple Controller with Mode (Black) ‐ PQRCVCL0Q
Simple Controller with Mode (White) ‐ PQRCVCL0QW
Simple Controller without Mode (Black) ‐ PQRCHCA0Q
Simple Controller without Mode (White) ‐ PQRCHCA0QW
AC Smart Premium ‐ PQCSW421E0A
ACP Premium ‐ PQCPC22A1
ACP Standard ‐ PQCPC22N1
LonWorks Gateway ‐ PQNFB16A1
BACnet Gateway ‐ PQNFB17B0
AC Ez ‐ PQCSZ250S0
Dry Contact Unit (1 contact, 24 VAC external power) ‐ PQDSB1
Dry Contact Unit (2 input, power from indoor unit) ‐ PQDSBC
Dry Contact for third party thermostat ‐ PQDSBNGCM1
For continual product development, LG reserves the right to change specifications without notice.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com
For:
File
Approval
GC:
Mech:
(Project Manager)
12,000
13,800
Heating Nominal Test Conditions:
Indoor:
70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
208‐230/60/1
0.20
1/4
3/8
13/16, 5/8
Thermistor
Tag #:
Resubmit
Other
Operating Range:
Cooling (°F WB)
Heating (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control
Sound Pressure² H/M/L (±3 dB(A))
Primary Filter
Secondary Filter
Net Unit Weight (lbs)
Shipping Weight (lbs)
Fan:
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
Notes:
1.Acceptable opera ng voltage: 187V ‐ 253V.
2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
3.See Engineering Manual for sensible and latent capaci es.
4.All power/communica on cable to be minimum 18 AWG, 4‐conductor, stranded,
shielded and must comply with applicable local and national code.
5.Power wiring cable size must comply with the applicable local and na onal code.
6.This unit comes with a dry helium charge.
7.Corresponding refrigerant piping length is in accordance with standard length of each
outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio
between 95 – 105%
8.Must follow installa on instruc ons in the applicable LG installa on manual.
57‐77
59‐81
R410A
39/36/31
Washable Pre‐filter
Plasma
Cross Flow
Brushless Digitally Controlled/Direct
335/318/300
DFS‐SB‐AD‐012‐US 013J10
Page 1 of 2
EEV
25
29
1