Problem
PureAV Battery
Backup not on,
LED not lit
PureAV
Battery Backup
always on battery
mode
Backup time
too short
The PureAV
Battery Backup
continuously beeps
Red LED lit
Possible Cause
On/Off/Test button not
pushed or pushed less
than 2 seconds
Battery voltage is too
low
Battery Backup fault
Power cord loose
AC breaker is burned
out or tripped
AC utility voltage is too
high or too low, or there
is a blackout
Battery not fully
charged
Battery Backup is
overloaded
Charger fault or other
reason
Overload
Battery failure
Solution
Press the On/Off/Test
button for more than 2
seconds
Recharge the Battery
Backup at least 8 hours
Contact Belkin Customer
Service
Re-plug the power cord
Replace or reset the breaker
Normal condition
Recharge the Battery
Backup at least 8 hours
Remove some unnecessary
loads
Replace battery.
Contact Belkin Customer
Service or go to belkin.com.
Remove the non-critical
loads
Replace battery.
Contact Belkin Customer
Service or go to belkin.com.