Troubleshooting

PROBLEM
POSSIBLE CAUSE
UPS not on
On/off/test/ button not
LED not lit
pushed or pushed less
than 1 second
Battery voltage less than
10V
Load less than 20W
at battery mode
UPS always at
Power cord loose
battery mode
AC fuse is burned out
Line voltage too high, too
low or black out
Back up time too short
Battery not fully charged
The UPS continuously
Overload
beeps
RED LED lit
Battery failure

Storage

11.0 Storage Conditions
Store the UPS covered and upright in a cool, dry location, with its
battery fully charged. Before storing, charge the UPS for at least 4
hours. Disconnect any cables connected to the computer interface
port to avoid unnecessary drainage of the battery.
11.1 Extended Storage
During extended storage in environments where the ambient
temperature is -15˚C to +30˚C (+5˚F to +86˚F), charge the UPS
battery every 6 months.
During extended storage in environments where the ambient
temperature is +30˚C to +45˚C (+86˚F to +113˚F), charge the UPS
battery every 3 months.
SOLUTION
Press the on/off/test button
more than 1 second
Recharge the UPS at least
4 hours
Normal condition
Replug the power cord
Replace the AC fuse
Normal condition
Recharge the UPS at
least 4 hours
Remove the
noncritical loads
Replace battery
14

Specifications

MODEL
INPUT
Capacity
Voltage
Frequency
OUTPUT
Voltage
(on battery)
Frequency
(on battery)
Voltage
Regulation
AVR
Transfer Time
PROTECTION AND
Spike Protection
FILTERING
EMI/RFI filter
Overload
Protection
Unit Input
10Base-T
Cable Port
Short Circuit
BATTERY
Type
Typical
Recharge Time
Protection
Back up Time
PHYSICAL
Net Weight
Kg(lbs)
Shipping Weight
Kg(lbs)
Dimension(mm)
WxDxH
Input Inlet
ALARM
Battery
Back-Up
Battery Low
Overload
INTERFACE
RS232
Interface
CONFORMANCE
Safety
Surge
ENVIRONMENT
Ambient operation
Audible noise
Storage condition
F6C325
F6C425
F6C525
F6C625
325VA
425VA
525VA
625VA
100V, 110V, 120V, ±25%
50Hz or 60Hz ±5% (auto sensing)
Simulated sine wave at Line Input ±5%
50Hz or 60Hz ±0.5%
AVR automatically increases output voltage
15% above input voltage if -9% to -25% of
nominal. AVR decreases output voltage
13% below input voltage if +9% to
25% of nominal
2-4 milliseconds, including detection time
320 Joules, 2ms
10dB at 15MHz,
50dB at 30MHz
UPS automatic shutdown if overload
exceeds 110% of nominal at 60 second
and 130% at 3 seconds
Fuse for overload and short circuit protection
Network (UTP, RJ45) compatible jacks
(F6C425, F6C525, F6C625)
UPS output cut off immediately or input
fuse protection
Sealed, maintenance-free lead acid
4 hours (to 90% of full capacity)
Automatic self-test and discharge protection,
replace battery indicator
Depending on computer load...
5-17 min.
5-24 min.
5-32 min.
5-41 min.
4.7(10.4)
5.8(12.8)
6.2(13.7)
6.5(14.3)
5.0(11.0)
6.1(13.4)
6.5(14.3)
6.9(15.2)
97
260
135
97x320x135
x
x
IEC 320 power inlet
Slow beeping sound (about 0.47Hz)
Rapid beeping sound (about 1.824Hz)
Continuous beeping sound
Bi-directional communication port
(F6C425, F6C525, F6C625)
cUL, TUV, CE, meet FCC
Meet IEEE 587 standard
6,000 meters max. elevation, 0-95% humidity
non-condensing, 0-48˚C
<40dBA (1 meter from surface)
15000 meters max. elevation
15