Introduction Congratulations and thank you for purchasing the PureAV Home Theater Battery Backup with AVR Technology (the PureAV Battery Backup). Frequent electrical disturbances, both natural and man-made, degrade the quality of power supplied to your home theater system. Brownouts or blackouts can cause you to lose your complex settings, and ultimately damage your valuable equipment along with the overall quality of your home theater experience.
PureAV Battery Backup Features and Functions On/Off/Test Switch Indicator Condition BATTERY ON (Green LED) Flashing OVERLOAD (Yellow LED) Flashing REPLACE BATTERY (Red LED) SITE WIRING FAULT (Red LED) LOAD (Yellow LED) BATTERY (Green LED) LEDs Indicator The PureAV Battery Backup is on battery back-up mode and an Intermittent audible Solid alarm is on.
Alarms Battery Backup (Slow Alarm) When the PureAV Battery Backup is in battery-backup mode, the “Battery On” LED (green) illuminates and the PureAV Battery Backup sounds an audible alarm. The alarm stops when the PureAV Battery Backup returns to normal online operation. Low Battery (Rapid Alarm) When the PureAV Battery Backup is in battery-backup mode and the battery’s energy begins to run low, the PureAV Battery Backup will beep...
Product Features Rear Panel A. Surge-Protection-Only Outlets Equipment such as printers, fax machines, scanners, or desk lamps can be plugged into these outlets. These outlets do not provide power during a power outage. These outlets are always on (when AC power is available) and are not controlled by the front-panel switch.
“REPLACE BATTERY” LED. The loads are not affected. Recharge the battery overnight and perform the self-test again. If the “REPLACE BATTERY” LED is still on, the battery will need to be replaced. Please contact Belkin Customer Service for assistance.
Connect a modular coaxial cable between the cable wall outlet and the surge protector jack marked “IN”. Connect another coaxial cable between the surge protector jack marked “OUT” and the cable equipment or cable modem being protected. *All equipment must be turned off prior to hardware installation.
Battery not fully charged Battery Backup is Remove some unnecessary overloaded reason Service or go to belkin.com. Overload Battery failure Service or go to belkin.com. Solution Press the On/Off/Test button for more than 2 seconds...
Belkin Corporation will spend, to repair or replace the damaged connected equipment, at Belkin’s option, an amount equal to the fair market value of the damaged equipment or the original purchase price of the equipment,...
Page 12
All above warranties are null and void if: the PureAV Battery Backup in use during the occurrence is not provided to Belkin Corporation for inspection upon Belkin’s request at the sole expense of the purchaser,...
Page 13
“Occurrence” and how to proceed with your claim. Please conveniently register your PureAV Battery Backup online on our website at www.belkin.com. Belkin Corporation • 501 West Walnut Street • Compton • CA • 90220 • Tel: 310.898.1100 • Fax: 310.898.1111...
On the battery, you will find the battery name. Please reference the chart below for recycling information. Battery Name BB Battery CSB Battery VISION Battery RITAR Battery Please visit belkin.com for battery replacement information Recycling Inside Recycling Outside the USA (800) 278-8599 (800) 738-7372 1 (817) 244-4415...