Belkin PureAV AP30800-10 User Manual

Belkin PureAV AP30800-10 User Manual

Home theater battery backup with avr technology

Advertisement

Clean Sound
Clear Picture
Home Theater Battery Backup with AVR Technology
User Manual
AP30800-10

Advertisement

Table of Contents
loading

Summary of Contents for Belkin PureAV AP30800-10

  • Page 1 Clean Sound Clear Picture Home Theater Battery Backup with AVR Technology User Manual AP30800-10...
  • Page 2: Table Of Contents

    Package Contents ... 2 PureAV Battery Backup Features and Functions ...3 Alarms ... 4 Product Features ... 5 Installation ... 6-7 Troubleshooting ... 8 Technical Specifications ... 9 Storage ... 9 Belkin Connected Equipment Warranty ... 10-12 Information ... 13...
  • Page 3: Introduction

    Introduction Congratulations and thank you for purchasing the PureAV Home Theater Battery Backup with AVR Technology (the PureAV Battery Backup). Frequent electrical disturbances, both natural and man-made, degrade the quality of power supplied to your home theater system. Brownouts or blackouts can cause you to lose your complex settings, and ultimately damage your valuable equipment along with the overall quality of your home theater experience.
  • Page 4: Pureav Battery Backup Features And Functions

    PureAV Battery Backup Features and Functions On/Off/Test Switch Indicator Condition BATTERY ON (Green LED) Flashing OVERLOAD (Yellow LED) Flashing REPLACE BATTERY (Red LED) SITE WIRING FAULT (Red LED) LOAD (Yellow LED) BATTERY (Green LED) LEDs Indicator The PureAV Battery Backup is on battery back-up mode and an Intermittent audible Solid alarm is on.
  • Page 5: Alarms

    Alarms Battery Backup (Slow Alarm) When the PureAV Battery Backup is in battery-backup mode, the “Battery On” LED (green) illuminates and the PureAV Battery Backup sounds an audible alarm. The alarm stops when the PureAV Battery Backup returns to normal online operation. Low Battery (Rapid Alarm) When the PureAV Battery Backup is in battery-backup mode and the battery’s energy begins to run low, the PureAV Battery Backup will beep...
  • Page 6: Product Features

    Product Features Rear Panel A. Surge-Protection-Only Outlets Equipment such as printers, fax machines, scanners, or desk lamps can be plugged into these outlets. These outlets do not provide power during a power outage. These outlets are always on (when AC power is available) and are not controlled by the front-panel switch.
  • Page 7: Installation

    “REPLACE BATTERY” LED. The loads are not affected. Recharge the battery overnight and perform the self-test again. If the “REPLACE BATTERY” LED is still on, the battery will need to be replaced. Please contact Belkin Customer Service for assistance.
  • Page 8: Installation

    Connect a modular coaxial cable between the cable wall outlet and the surge protector jack marked “IN”. Connect another coaxial cable between the surge protector jack marked “OUT” and the cable equipment or cable modem being protected. *All equipment must be turned off prior to hardware installation.
  • Page 9: Troubleshooting

    Battery not fully charged Battery Backup is Remove some unnecessary overloaded reason Service or go to belkin.com. Overload Battery failure Service or go to belkin.com. Solution Press the On/Off/Test button for more than 2 seconds...
  • Page 10: Technical Specifications

    15%-100% load Typical Recharge Time Ambient Operation Surge Dimension (W x H x D) Net Weight AP30800-10 1200VA/640W 90-136VAC 60Hz ( ±3Hz ) Simulated sine wave, 120VAC ±8% 60Hz ( ±1Hz ) 1.5~40 min. ≤ 12 hours recover 85% capacity 0~85% humidity non-condensing, 0~35°C...
  • Page 11: Belkin Connected Equipment Warranty

    Belkin Corporation will spend, to repair or replace the damaged connected equipment, at Belkin’s option, an amount equal to the fair market value of the damaged equipment or the original purchase price of the equipment,...
  • Page 12 All above warranties are null and void if: the PureAV Battery Backup in use during the occurrence is not provided to Belkin Corporation for inspection upon Belkin’s request at the sole expense of the purchaser,...
  • Page 13 “Occurrence” and how to proceed with your claim. Please conveniently register your PureAV Battery Backup online on our website at www.belkin.com. Belkin Corporation • 501 West Walnut Street • Compton • CA • 90220 • Tel: 310.898.1100 • Fax: 310.898.1111...
  • Page 14: Information

    On the battery, you will find the battery name. Please reference the chart below for recycling information. Battery Name BB Battery CSB Battery VISION Battery RITAR Battery Please visit belkin.com for battery replacement information Recycling Inside Recycling Outside the USA (800) 278-8599 (800) 738-7372 1 (817) 244-4415...
  • Page 16 Boeing Avenue 333 1119 PH Schiphol-Rijk, The Netherlands Tel: +31 (0) 20 654 7300 Fax: +31 (0) 20 654 7349 © 2005 Belkin Corporation. All rights reserved. All trade names are registered trademarks of respective manufacturers listed. P74699-A Belkin Ltd.