Table Of Contents; Safety Precautions - Fujitsu ASYG07KMTB Operating Manual

Hide thumbs Also See for ASYG07KMTB:
Table of Contents

Advertisement

[Original Instructions]
Contents
1. SAFETY PRECAUTIONS .......................................... 1
2. PREPARATION ......................................................... 2
3. NAME OF PARTS ..................................................... 3
3.1. Indoor unit ........................................................ 3
3.2. Remote controller ............................................. 3
4. BASIC OPERATIONS ............................................... 5
5. AIRFLOW SETTINGS ............................................... 5
5.1. Fan speed setting ............................................. 5
5.2. Airflow direction setting .................................... 5
6. TIMER OPERATIONS ............................................... 5
6.1. On timer or Off timer ......................................... 5
6.2. Program timer ................................................... 5
6.3. Sleep timer ...................................................... 6
7. ENERGY SAVING OPERATIONS ............................ 6
7.1. Economy operation .......................................... 6
8. OTHER OPERATIONS ............................................. 6
8.1. Powerful operation ........................................... 6
8.3. 10 °C Heat operation ........................................ 6
9. SETTINGS ON INSTALLATION ................................ 7
10. CLEANING AND CARE ............................................. 7
11. GENERAL INFORMATION ....................................... 9
12. OPTIONAL PARTS ................................................... 9
12.1. Wired remote controller .................................... 9
12.2. Wireless LAN control ........................................ 9
12.3. Multi-type air conditioner .................................. 9
13. TROUBLESHOOTING ............................................ 10

1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section
carefully before you use this product, and be sure to comply
with the following safety precautions.
Incorrect operation due to failure to follow the instructions may
cause harm or damage, the seriousness of which is classified
as follows:
This mark warns of death or serious injury.
This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this product uses a
flammable refrigerant. If the refrigerant is leaked and
exposed to an external ignition source, there is a risk
of fire.
En-1
WARNING
CAUTION
CAUTION
This symbol shows that the operating manual should
be read carefully.
CAUTION
This symbol shows that a service personnel should
be handling this equipment with reference to the
installation manual.
CAUTION
This symbol shows that information is available such
as the operating manual or installation manual.
WARNING
• The appliance shall be installed, operated and stored
in a room with a floor area larger than X m².
Amount of refrigerant charge
M (kg)
M ≤ 1.22
1.22 < M ≤ 1.23
1.23 < M ≤ 1.50
1.50 < M ≤ 1.75
1.75 < M ≤ 2.0
2.0 < M ≤ 2.5
2.5 < M ≤ 3.0
3.0 < M ≤ 3.5
3.5 < M ≤ 4.0
• This product contains no user-serviceable parts.
Always consult authorized service personnel for
repairing, installation, and relocation of this product.
Improper installation or handling will cause leakage,
electric shock, or fire.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the
electrical breaker or disconnecting the power plug.
Then consult authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should be replaced only by
authorized service personnel in order to avoid a
hazard.
• In the event of refrigerant leakage, be sure to keep
away from fire or any flammables, and consult
authorized service personnel.
• In the event of a thunder storm or any prior sign
of a lightning strike, turn off the air conditioner via
the remote controller, and refrain from touching the
product or the power source to prevent any electrical
hazards.
• This product shall be stored in a room without
continuously operating ignition sources (for example:
open flames, an operating gas appliance or an
operating electric heater).
• This product shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• This product shall be stored so as to prevent
mechanical damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit,
pipes shall be covered with the wall hook bracket for
protection.
Do not move this product by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
flammable gas to leak during operation).
Minimum room area
2
X (m
)
-
1.45
2.15
2.92
3.82
5.96
8.59
11.68
15.26
(IEC 60335-2-40)