Variable address
Description
Filter factor for temperature on analog input Temp
55
Low pass filter to avoid temperature spikes and flickering.
Calibration of the internal temperature sensor
56
Is used to correct the internal temperature reading if necessary.
Display setting for Active mode
0 = Show the calculated setpoint (SP calc ) 1 =
57
Show the room temperature
Display setting for the Setpoint mode
0 = Show the calculated setpoint (SP calc )
58
1 = Show the user defined setpoint adjustment (SP adj )
59
Intensity or "brightness" of display when in Active or Setpoint mode
60
Intensity or "brightness" of display when in Idle mode
61
The Modbus address the controller uses
Modbus stop bits and parity
62
0 = 8N2 1 = 8O1 2 = 8E1 3 = 8N1
Timeout should be at least 1.5 times a character,
63
i.e. at least 2 ms (@9 600 baud)
Answer delay should be at least 3.5 times a character,
64
i.e. at least 5 ms (@9 600 baud)
0 = 4800 bps
65
2 = 19200 bps

13. Optional Wired remote controller for EC fan: PAW-FC-907TC

The PAW-FC-907TC thermostat is optimized for office building,
hotel, hospital and residential applications.
It can be used for 2-pipe or 4-pipe applications and is available
in a housing finish with white glass display with mechanical
buttons on a white base.
The PAW-FC-907TC thermostat is both easy to operate and
install. The devices feature microprocessor-based control and
large backlit LCD screens which display operation status (cooling,
heating, and ventilation), fan speed, room temperature and set-
point.
WARNING: HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
Follow safe electrical work practices and applicable local
codes.
Read and understand the instructions before installing
the product. Follow the instructions during installation.
Installation, wiring, testing or service must be performed
only by qualified persons in accordance with all
applicable codes and regulations.
Do not use the product for life or safety applications.
Do not install the product in hazardous or classified
locations.
Do not exceed the product's ratings or maximum limits.
The product may use multiple voltage/power sources.
A qualified person is one who has skills and knowledge related to the construction and operation of this electrical equipment and
installations, and has received safety training to recognize and avoid the hazards involved.
If this product is used in a manner not specified by the manufacturer, the protection provided by the product may be impaired.
No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
1 = 9600 bps
3 = 38400 bps
Failure to follow these instructions will result in death or serious injury.
Unit
%
-
-
-
%
%
-
-
ms
ms
-
Turn off ALL power supplying equipment before working
on or inside the equipment.
Use a properly rated voltage sensing device to confirm
that all power is off.
Do NOT depend on the product for voltage indication.
Products rated only for basic insulation must be installed
on insulated conductors.
Current transformer secondaries (current mode) must be
shorted or connected to a burden at all times.
Remove all wire scraps and tools, replace all doors,
covers and protective devices before powering the
equipment.
33
Default
Min
Scale
value
value
20
1
0
0
10
-100
1
1
0
0
1
0
70
1
0
25
1
0
1
1
1
2
1
0
3
1
1
5
1
1
1
1
0
Max
valu
e
100
100
1
1
100
100
254
3
500
500
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents