Outdoor air
temp
℃ DB
℃ WB
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-13.7
-15.0
-11.8
-13.0
-9.8
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
70%
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
18.0
16.8
20.0
18.5
24.0
20.5
-19.8
-20.0
-18.8
-19.0
-16.7
-17.0
-13.7
-15.0
-11.8
-13.0
-9.8
-11.0
-9.5
-10.0
-8.5
-9.1
-7.0
-7.6
-5.0
-5.6
-3.0
-3.7
60%
0.0
-0.7
3.0
2.2
5.0
4.1
7.0
6.0
9.0
7.9
11.0
9.8
13.0
11.8
15.0
13.7
18.0
16.8
20.0
18.5
24.0
20.5
64
16
18
TC
PI
TC
PI
kW
kW
kW
kW
20.1
7.00
18.9
6.77
20.3
7.01
18.9
6.70
20.3
6.86
19.0
6.55
20.3
6.70
19.0
6.42
20.3
6.54
19.0
6.23
20.4
6.36
19.0
6.00
20.4
6.26
19.0
5.83
20.4
6.16
19.0
5.67
20.3
5.88
19.0
5.41
20.2
5.49
18.9
5.06
20.2
5.17
18.9
4.77
20.2
4.70
18.9
4.37
20.2
4.30
18.9
0.10
20.2
4.06
18.9
3.75
20.2
3.83
18.9
3.55
20.2
3.62
18.9
3.36
20.2
3.43
18.9
3.18
20.2
3.24
18.9
3.01
20.2
3.07
18.9
2.85
20.2
2.91
18.9
2.71
20.2
2.78
18.9
2.58
20.2
2.65
18.9
2.47
17.4
6.46
16.3
6.19
17.4
6.41
16.3
6.11
17.4
6.25
16.3
5.87
17.5
6.05
16.4
5.59
17.5
5.73
16.4
5.29
17.5
5.42
16.4
5.01
17.5
5.27
16.4
4.87
17.5
5.13
16.4
4.75
17.5
4.90
16.4
4.54
17.4
4.58
16.3
4.25
17.4
4.33
16.3
4.02
17.4
3.95
16.3
3.68
17.4
3.63
16.3
3.38
17.4
3.43
16.3
3.19
17.4
3.25
16.3
3.03
17.4
3.07
16.3
2.87
17.4
2.92
16.3
2.73
17.4
2.76
16.3
2.58
17.4
2.63
16.3
2.45
17.4
2.51
16.3
2.33
17.3
2.40
16.3
2.23
17.3
2.31
16.3
2.14
Indoor air temperature ℃ DB
20
21
TC
PI
TC
PI
kW
kW
kW
kW
17.7
6.35
17.0
6.20
17.7
6.31
17.0
6.15
17.7
6.16
17.0
6.01
17.7
6.01
17.0
50.01
17.7
5.73
17.0
5.52
17.8
5.43
17.1
5.22
17.8
5.28
17.1
5.08
17.8
5.14
17.1
4.94
17.7
4.91
17.0
4.73
17.6
4.60
16.9
4.42
17.6
4.34
16.9
4.18
17.6
3.97
16.9
3.82
17.6
3.64
16.9
3.51
17.6
3.45
16.9
3.32
17.6
3.26
16.9
3.14
17.6
3.09
16.9
2.98
17.6
2.93
16.9
2.83
17.6
2.77
16.9
2.68
17.6
2.63
16.9
2.55
17.6
2.51
16.9
2.42
17.6
2.39
16.9
2.31
17.6
2.30
16.9
2.22
15.1
5.62
14.6
5.40
15.1
5.51
14.6
5.30
15.1
5.26
14.6
5.06
15.2
5.02
14.6
4.83
15.2
4.76
14.6
4.59
15.2
4.52
14.7
4.35
15.2
4.40
14.7
4.24
15.2
4.29
14.7
4.13
15.2
4.10
14.6
3.95
15.1
3.85
14.6
3.71
15.1
3.66
14.6
3.51
15.1
3.34
14.6
3.23
15.1
3.08
14.6
2.97
15.1
2.92
14.6
2.82
15.1
2.76
14.6
2.67
15.1
2.63
14.6
2.54
15.1
2.50
14.6
2.41
15.1
2.37
14.6
2.29
15.1
2.26
14.6
2.18
15.1
2.16
14.6
2.09
15.1
2.07
14.6
2.01
15.1
1.99
14.6
1.94
22
24
TC
PI
TC
PI
kW
kW
kW
kW
16.4
6.07
15.5
5.85
16.4
6.02
15.5
5.73
16.4
5.86
15.5
5.47
16.4
5.58
15.5
5.20
16.4
5.29
15.5
4.93
16.4
5.01
15.5
4.67
16.4
4.87
15.5
4.54
16.4
4.75
15.5
4.42
16.4
4.54
15.5
4.24
16.4
4.28
15.5
4.00
16.4
4.04
15.5
3.78
16.4
3.70
15.5
3.46
16.4
3.40
15.5
3.18
16.4
3.22
15.5
3.01
16.4
3.05
15.5
2.86
16.4
2.89
15.5
2.71
16.4
2.74
15.5
2.58
16.4
2.60
15.5
2.45
16.4
2.47
15.5
2.33
16.4
2.35
15.5
2.23
16.4
2.25
15.5
2.14
16.4
2.17
15.5
2.06
14.2
5.25
13.3
4.84
14.2
5.13
13.3
4.73
14.2
4.90
13.3
4.53
14.2
4.67
13.3
4.31
14.2
4.44
13.3
4.10
14.2
4.20
13.3
3.89
14.2
4.09
13.3
3.78
14.2
3.99
13.3
3.69
14.2
3.82
13.3
3.55
14.2
3.61
13.3
3.35
14.2
3.42
13.3
3.17
14.2
3.14
13.3
2.92
14.2
2.90
13.3
0.12
14.2
2.74
13.3
2.56
14.2
2.61
13.3
2.43
14.2
2.48
13.3
2.32
14.2
2.35
13.3
2.21
14.2
2.24
13.3
2.10
14.2
2.14
13.3
2.00
14.2
2.05
13.3
1.92
14.2
1.97
13.3
1.85
14.2
1.91
13.3
1.78