BGH GMV6 Technical Sales Manual page 37

Table of Contents

Advertisement

Outdoor
14.0 ℃ WB
air temp
20.0 ℃ DB
(℃ DB )
TC
kW
-5
13.6
0
13.6
4
13.6
7
13.6
10
13.6
12
13.6
14
13.6
16
13.6
18
13.6
20
13.6
21
13.6
23
13.6
25
13.6
27
13.6
50%
29
13.6
31
13.6
33
13.6
35
13.6
37
13.6
39
13.6
41
13.6
43
13.6
44
13.2
46
12.5
47
12.1
50
10.4
52
8.1
53
6.8
55
6.3
17.0 ℃ WB
18.0 ℃ WB
24.0 ℃ DB
26.0 ℃ DB
PI
TC
PI
TC
kW
kW
kW
kW
1.26
16.2
1.50
19.3
1.26
16.2
1.51
19.3
1.26
16.2
1.51
19.3
1.29
16.2
1.54
19.3
1.67
16.2
1.93
19.3
1.68
16.2
1.95
19.3
1.71
16.2
1.98
19.3
1.73
16.2
2.00
19.3
1.76
16.2
2.04
19.3
1.78
16.2
2.07
19.3
1.79
16.2
2.09
19.3
1.82
16.2
2.12
19.3
1.84
16.2
2.15
19.3
1.88
16.2
2.24
19.3
1.98
16.2
2.36
19.3
2.09
16.2
2.50
19.3
2.22
16.2
2.65
19.3
2.34
16.2
2.80
19.3
2.46
16.2
2.96
19.3
2.60
16.2
3.12
19.3
2.95
16.2
3.53
19.3
3.08
16.2
3.70
19.2
3.21
15.9
3.84
18.6
4.1
15.2
4.6
18.1
4.62
14.9
4.95
17.8
4.48
13.0
4.87
15.9
3.33
10.9
4.15
13.5
2.77
9.0
3.41
11.8
2.59
8.2
3.11
10.7
GMV6 DC Inverter VRF Units
Indoor air temp
19.0 ℃ WB
20.0 ℃ WB
27.0 ℃ DB
28.0 ℃ DB
PI
TC
PI
TC
kW
kW
kW
kW
1.78
20.1
1.92
21.4
1.78
20.1
1.92
21.4
1.79
20.1
1.93
21.4
1.82
20.1
1.96
21.4
2.20
20.1
2.34
21.4
2.24
20.1
2.37
21.4
2.27
20.1
2.42
21.4
2.30
20.1
2.45
21.4
2.34
20.1
2.49
21.4
2.38
20.1
2.54
21.4
2.40
20.1
2.55
21.4
2.44
20.1
2.60
21.4
2.49
20.1
2.65
21.4
2.63
20.1
2.83
21.4
2.79
20.1
3.00
21.4
2.97
20.1
3.19
21.4
3.14
20.1
3.37
21.4
3.31
20.1
3.57
21.4
3.51
20.1
3.78
21.4
3.71
20.1
4.00
21.9
4.17
20.1
4.14
21.1
4.39
20.1
4.44
21.1
4.64
19.8
4.32
21.0
4.8
19.1
4.6
20.4
4.87
18.8
4.75
20.2
5.13
17.0
5.14
18.5
4.67
14.9
4.90
15.0
4.07
12.9
4.24
13.1
3.70
11.4
3.74
11.9
Technical Sales Guide
22.0 ℃ WB
24.0 ℃ WB
30.0 ℃ DB
32.0 ℃ DB
PI
TC
PI
TC
kW
kW
kW
kW
2.08
24.9
2.41
26.8
2.08
24.9
2.41
26.8
2.09
24.9
2.42
26.8
2.13
24.7
2.46
26.8
2.49
24.1
2.80
26.8
2.54
24.1
2.85
26.8
2.58
24.1
2.90
26.8
2.61
24.1
2.95
26.8
2.66
24.1
3.00
26.8
2.71
24.1
3.06
26.8
2.74
24.1
3.09
26.8
2.79
24.1
3.14
26.8
2.88
24.1
3.30
26.8
3.05
24.1
3.51
26.8
3.25
24.1
3.73
26.8
3.45
24.1
3.97
26.8
3.66
24.1
4.22
26.8
3.87
24.1
4.48
26.8
4.11
24.1
4.75
26.8
4.36
24.1
5.04
26.8
4.49
23.3
5.20
25.5
4.66
23.1
5.33
24.9
4.84
23.2
5.47
25.2
5.0
22.6
5.7
24.6
5.15
22.3
5.87
24.3
5.50
21.0
6.27
23.2
4.74
15.3
4.68
16.2
4.15
13.6
4.15
14.1
3.76
12.4
3.80
13.0
PI
kW
2.75
2.76
2.77
2.82
3.12
3.17
3.24
3.29
3.35
3.41
3.45
3.52
3.76
4.01
4.27
4.54
4.83
5.13
5.45
5.79
5.95
6.10
6.26
6.6
6.72
7.03
4.80
4.18
3.86
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents