Viessmann VITOSOL 200-FM SV2F Design Manual page 52

Flat plate solar collectors
Hide thumbs Also See for VITOSOL 200-FM SV2F:
Table of Contents

Advertisement

Design Information
Vitosol 200-FM Flat-Plate Collectors
Type SH — angle of inclination α 50 to 80°
Legend
A Base rail
B Adjustable support
C Collector support
Type SV and SH — installation on an on-site
substructure, e.g. steel beams
Legend
A Connecting brace
B Connecting ties
52
(on supports)
(continued)
Collector support base rail (Type SH)
Dimensions:
a
3 in. (80 mm)
b
3 in. (75 mm)
c
Ø 0.4 in. (11 mm)
d
2 in. (50 mm)
e
28b in. (722 mm)
f
35a in. (897 mm)
g
4 in. (100 mm)
Note: Imperial dimensions are
rounded to the nearest a in.
x
in. (mm)
y
in. (mm)
z
in. (mm)
x
in. (mm)
y
in. (mm)
z
in. (mm)
Solar System Design Guide
Vitosol 200-FM, Type SV
23½ (595)
18
7
/
(481)
8
See page 56
Vitosol 200-FM, Type SH
75f (1920)
18
7
/
(481)
8
See page 56

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitosol 200-fm sh2f

Table of Contents