MAINTENANCE AND CLEANING 
For cleaning and maintenance, first separate the filter 
unit from the pump unit and then remove both units 
from the water. 
 Maintenance of the pump unit involves cleaning the 
central outlet, flow‐out nozzles and impeller unit. 
If  necessary,  clean  with  clear  water  using  a  soft
brush. 
Do  not  use  cleaning  agents  or  chemical  solutions. 
We recommend using OASE PumpClean for remov‐
ing calcium deposits. 
Cleaning  and  replacement  cycles  for  filter  media 
such as foam filters are dependent on the size of the 
aquarium  and  the  number  of  fish.  Therefore,  it  is 
necessary  to  clean  and  replace  the  filter  media  as 
required to ensure optimum filter performance.
 If there are several foam filters: Clean or replace the 
foam  filters  at  different  times.  This  saves  enough 
useful  bacteria  to  ensure  good  biological  filtration 
of the water. 
 Recommendation for clear water: Replace the filter
fleece  at  least  each  time  the  filter  sponges  are
cleaned. 
Cleaning or replacing the filter media 
 F 
 Carefully  pull  the  filter  unit  from  the  pump  unit
(magnetic holder) and remove from the aquarium. 
 Separate the filter modules (press the button).
 Empty  the  filter  modules  over  a  wash  basin  and 
rinse the foam filters or filter fleece under warm wa‐
ter or replace.
Cleaning the heater unit 
 C 
 BioPlus Thermo: Remove the heater and clean ac‐
cording to the separately enclosed instructions. 
 Also clean the chamber for the heater.
 
Pump unit maintenance 
 G 
 Remove the pump unit. 
– Release the suction cups with the aid of the tab.
 Pull up the nozzle unit and separate it from the base 
plate. 
 Clean the central outlet and flow‐out nozzles. 
 Reassemble the unit in the reverse order.
 H 
 Pull the pump lid off downward.
 Remove the impeller unit, clean or replace.
 Reassemble the unit in the reverse order.
 
– Ensure that the two rubber bearings are correctly
seated. 
10 
Re‐installing the unit 
 Fit the pump unit and filter unit together again, and 
install  and  connect  as  before  in  the  aquarium 
(→ Installation and connection): 
– Flow‐out  nozzles  just  below  the  surface  of  the
water 
– Outlet control knob adjusted as required 
– Power connection cables with drip loop
WEAR PARTS 
The following components are wear parts and are ex‐
cluded from the warranty: 
 Filter fleece
 Foam filter
 Suction cups
 Impeller unit
 
DISPOSAL 
Do not dispose of this unit with domestic waste! For 
disposal purposes, please use the return system pro‐
vided. Render the unit unusable beforehand by cutting 
the cables. 
 

SPARE PARTS

The use of original parts from OASE ensures continued
safe and reliable operation of the unit. Please visit our
website for spare parts drawings and spare parts.
https://www.oase-livingwater.com
BioPlus 50/100/200, BioPlus Thermo 50/100/200

Hide quick links:

Advertisement

Table of Contents
loading