REMEDY OF FAULTS

Malfunction
Unit does not start up.
Water flow insufficient
Insufficient filtering performance Foam filter clogged
Increased noise

MAINTENANCE AND CLEANING

• If necessary, clean with clear water using a soft
brush.
• Do not use cleaning agents or chemical solutions.
We recommend using OASE PumpClean for remov-
ing calcium deposits.
• Cleaning and replacement cycles for filter media
are dependent on the size of the aquarium and the
number of fish. Therefore, it is necessary to clean
and replace the filter media as required to ensure
optimum filter performance.
Cleaning/replacing the filter media
N O T E
Thoroughly rinse out all filter material with warm tap
water before using for the first time in order to
remove any soiling. (→ Cleaning/replacing the filter
media)
Prerequisite
• The unit head is removed. (→ Dismantling the unit
head)
How to proceed:
 K, L
• Remove the foam filter and rinse in warm water or
replace.
• Rinse the ceramic substrate in warm water or
replace.
– Before using for the first time, remove the ce-
ramic substrate from the plastic bag, rinse it in
warm water and put it loosely into the filter con-
tainer.
Cause
No mains voltage
Impeller unit blocked
Water level in the unit too low
Filter housing or impeller unit soiled
Impeller unit worn
Foam filter clogged
Ceramic substrate soiled
Suction basket clogged
Pipework soiled
Foam filter worn
Ceramic substrate soiled
Ceramic substrate worn
Air in the filter, vent hose on the pump not correctly
positioned.
Remedy
Check the mains voltage.
Clean
Top up water
Clean
Replace the impeller unit.
Clean
Clean
Clean suction basket.
Clean suction unit, flow-out unit
and hoses.
Clean
Replace
Clean
Replace
Correct the position of the vent
hose.
Cleaning/replacing the impeller unit
Prerequisite
• The unit head is removed. (→ Dismantling the unit
head)
How to proceed:
 M
• Pull the pump lid off downward.
• Remove the impeller unit, clean or replace.
• Reassemble the unit in the reverse order.
– Ensure that the two rubber bearings are correct-
ly seated.
– Ensure that the vent hose is in place and is
pointing upwards so that the air can escape.
Re-installing the unit
• Reassemble the unit head and filter unit. (→ Fitting
the unit head)

WEAR PARTS

• Foam filters
• Ceramic substrate
• Impeller unit
• Suction cups