User Guide
Installer and Users please note:
These instructions should be read carefully and left with
the user of the product for future reference.
The Spectre must be installed by a competent electrician in
accordance with the current IEE wiring regulations.
Fix the Spectre with the hanging bracket provided. If the Spectre
is to be mounted with the bracket below the product, then remove
the handle, and re-assemble beneath the product. The Spectre
must be installed the correct way up. Installing the Spectre upside
down will seriously affect lamp life.
To comply with Health and Safety legislation, a safety chain must
be employed. A loop is provided at the top of the rear panel for
fixing the safety chain.
0.8m
Ensure that there are no obstructions to the ventilation, the air
intakes are around the edges of the colour-filter frame, and hot air
is exhausted through the fan. Also ensure that there are no
readily flammable items in contact with the case.
The Spectre is only intended for use indoors.
Connect the Spectre to the mains supply using the lead provided.
• Brown = live
• Blue = neutral
• Green/yellow = earth.
• The Spectre must be earthed
The supply must be fitted with an isolating switch, or plug and
socket, and protected by fuse or circuit breaker rated at either
10A and 16A. If the Spectre circuit is connected via an MCB then
it is recommended that a time-delay MCB is used (Type 3 or Type
C to BS3871). This will reduce the possibility of "nuisance tripping"
due to the large inrush current of the halogen lamps.
It is not recommended that the Spectre is connected to a
switching pack.