Installing the SPA1
CAUTIONS:
!
1.
Connection to the protective bonding circuit: provision for connecting the complete machine to the
protective ground (earthing) is the responsibility of the manufacturer or equipment installer.
2.
Isolation: the SPA1 is isolated by removing the mains connector. It is the responsibility of the
equipment installer or user to fit additional means of isolation if indicated by risk assessment.
3.
Earth fault/residual current protection: It is the responsibility of the machine's manufacturer or
product installer to ensure an adequate level of protection for the complete machine installation.
NOTE: All of the 'Mini Maestro™' drives must be securely connected to the SPA1 otherwise the
emergency stop will be activated.

4.1 Preparation of SPA1 service pack

The SPA1 service pack contains all the components required to construct the following items, which will
assist in the connection and set-up of the SPA1 unit.
4.1.1

Motor connectors

The service pack contains three motor connectors that fit the motor output from the SPA1.
Each of the three connector assemblies consist of the following:
• 1 off metal backshell
• 1 off power and signal D-type connector
• 2 off power pins
The power and signal D-type and power pins are of the solder bucket variety and should be fitted to the
CMM's wiring by a competent technician or engineer.