2 Safety notes

2.1 Correct use
Safety in operation is only guaranteed if the boiler con-
nection system is used correctly.
The boiler connection system "Regumat" allows a
time- and space-saving connection of the boiler to
the pipework.
Any use of the boiler connection system outside the
above applications will be considered as non-compli-
ant and misuse. Claims of any kind against the manu-
facturer and/or his authorised representatives due to
damages caused by incorrect use cannot be accep-
ted.
The observance of the installation and operating in-
structions is part of the compliance terms.
2.2 Possible dangers at the installation locati-
on and during transport
The case of an external fire has not been taken into
consideration when constructing the boiler connection
system.
WARNING
Heavy product group
Risk of injury Suitable transport and lifting devi-
ces are to be used. Wear suitable protective clot-
hing (e.g. safety shoes) during installation and use
safety devices. External components like hand-
wheels or pressure test points must not be mis-
used for the absorption of external forces, e.g. as
connection point for lever tools etc.
Hot and cold surfaces
Risk of injury Do not touch the boiler connection
system without safety gloves. It may get very hot
during operation.
Sharp edges
Risk of injury Only touch with safety gloves. Threads,
bore holes and edges are sharp.
Allergies
Health hazard Do not touch the boiler connection
system and avoid any contact if allergies against
the used materials are known.
3 Transport, storage and packa-
ging
3.1 Extent of supply
– Pre-assembled "Regumat" DN25 product group
– Thermal insulation
– "Regumat-130": with standard thermal insulation;
consisting of front and rear insulation shell
– "Regumat-180": with universal thermal insulation
of modular construction; consisting of front and
rear insulation shell and insertion block suitable
for the installation of standard high-efficiency
pumps
– Sealing set (4 fold)
– Pump installation set (stations without pump)
10
3.2 Transport inspection
Upon receipt check delivery for any damages caused
during transit.
Any damage must be reported immediately upon re-
ceipt.
3.3 Packaging
Packaging material is to be disposed of environmen-
tally friendly.

4 Technical data

4.1 Models
These installations and operating instructions are valid
for the following "Regumat" models:
For pumps with a length of 130mm:
– "Regumat S-130" DN 25 with standard thermal in-
sulation
– "Regumat M3-130" DN 25 with standard thermal
insulation
– "Regumat M4-130" DN 25 with standard thermal
insulation
For pumps with a length of 180mm:
– "Regumat S-180" DN 25 with universal thermal
insulation
– "Regumat M3-180" DN 25 with universal thermal
insulation
– "Regumat M4-180" DN 25 with universal thermal
insulation
– "Regumat S-180" DN 25 with pump ball valve with
universal thermal insulation
– "Regumat M3-180" DN 25 with pump ball valve with
universal thermal insulation
– "Regumat M4-180" DN 25 with pump ball valve with
universal thermal insulation
4.2 Performance data
Nominal dimension
Max. operating temperature
for standard pumps
Max. operating temperature
for high-efficiency pumps with
standard thermal insulation
Max. operating temperature
for high-efficiency pumps with
universal thermal insulation
Max. operating pressure p
Opening pressure of the
check valve
Kv-value
"Regumat S"
"Regumat M3"
"Regumat M4"
Distance between pipe centres 125 mm
Connections
Fluids: Non-aggressive fluids (e.g. water and suitable
water and glycol mixtures according to VDI 2035). Not
suitable for steam or oily and aggressive fluids.
DANGER
Suitable measures (e.g. safety valves) have to be
taken to ensure that the maximum working pres-
sures and maximum and minimum working tem-
peratures are not exceeded or undercut.
DN 25
+110°C
+85°C
+95°C
10 bar
s
20 mbar
7.4
4.3
4.2
G1½ flat sealing

Advertisement

Table of Contents
loading

Table of Contents