Technical Data; Fault Description - Bauer Magnum SM 540 Operating Manual

Gear pumps
Table of Contents

Advertisement

8 TECHNICAL DATA

Driving power
Driving speed
Discharge
Manometric head
Oil filling – gearbox „Spirax EP 90"
Oil reservoir for mechanical seal - hydraulic oil Shell Tellus S 22
Oil filling for self primer – hydraulic oil Shell Tellus S 22

9 FAULT DESCRIPTION

Fault
Water level drops during filling
The pump does not deliver
Discharge decreases.
Priming procedure with self primer
is interrupted.
24
Cause
Foreign object blocked between
suction pipe and the foot valve.
Rubber on foot valve damaged.
Suction head too high.
Leak or blockage in the suction line.
Too much solids.
Wrong direction of rotation.
Seal damage.
Too much counter-pressure
Suction line blocked.
Impeller blocked.
Ball has got caught.
Leaking joints or hoses.
Defective mechanical seal.
SM 540
kW
55
min -1
540
m 3 /h
40-200
m
95-52
1,0 lit
Remedy
Open and close the flap several
times.
Replace rubber.
Decrease suction head.
Repair defective parts or remove
blockage.
Add water.
Reverse direction of rotation.
Replace the seal.
Remove foreign object.
Clean suction line.
Clean impeller.
Open the coupling and close it
again.
Replace couplings or hoses.
Replace mechanical seal.
Operating manual for BAUER gear pump
SM 1000
SM 2000
108
1000
40 - 300
142 – 102
2,5 lit
0,4 lit
0,2 lit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum sm 1000Magnum sm 2000

Table of Contents