4.2 Gear pump with self-priming unit
WARNING!
Position the pump as close to the pumped medium as it is safe to do so.
Operating manual for BAUER gear pump
Check oil level in the gearbox and in the oil reservoir before every start!
•
•
•
•
•
•
Couple the suction line with the pump's suction
connection.
Always use the shortest possible suction pipe
Check that all connections are air-tight and that the
suction hose is in good condition
Always ensure the pumped medium is homogeneous
– DO NOT OVER MIX! Air in the slurry affects
performance & can cause serious pump damage by
cavitation.
Difficult suction conditions can seriously affect the
performance of the pump and lead to cavitation
Always fill up the pump with about 3 litres of water
through the side branch of the delivery socket.
9