Download Print this page

EcoFlow RIVER Pro User Manual page 12

Hide thumbs Also See for RIVER Pro:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
*If the product is not operating properly or the icon keep flashing, please contact the customer support
team. Do not charge the unit.
7
Communication Failure
between Main Board and
AC
Inverter Output Overload
Inverter High Temperature
Protection
Inverter Low Temperture
Protection
Fan Blockage
Car Charger Overload
Car Charger High
Temparature Protection
AC icon Flashes. Restart RIVER Pro.
AC and Overload icons flash together.
Turn off RIVER Pro. Unplug all appliances. Wait 10
seconds, turn System Power ON then AC Power
ON and plug each appliance back in in turn. If the
icons keep flashing, do not charge or discharge
the unit. Please note that electrical appliances
must be operated within rated power. (For more
information about X-Boost function, go to P10.
AC and High-temperature icons flash together.
Turn off RIVER Pro and let it cool down. Then turn
System Power On and AC Power On.
The AC and Low-Temperature icons flash together.
Turn off RIVER Pro, move RIVER Pro to a warmer
place and wait for the inverter to warm up. Then turn
System Power On and AC Power On.
Fan icon flashes. Turn Off RIVER Pro and carefully
clean and vacuum around vents at both sides of the
RIVER Pro. Turn System Power On.
Car and OVERLOAD icons flash together.
Restart RIVER Pro, and make sure that electrical appli-
ances must be operated within rated power.
Car and High-Temperature icons flash together.
Turn RIVER Pro off and let it cool down. Turn System
Power On then DC Power On.

Hide quick links:

Advertisement

loading