Hussmann Entyce TY3 Series Installation & Operation Manual page 18

Hide thumbs Also See for Entyce TY3 Series:
Table of Contents

Advertisement

SELF SERVICE MULTI-DECK HOT CASE
HUSSMANN -
TY3-4X
ELECTRICAL DATA:
TOTAL
208 VOLT
HOT
VOLTS
PH HZ
MODELS
LEVELS
***
TY3-4X4E-H
208
3
60
2
TY3-4X5E-H
208
3
60
2
TOTAL
240 VOLT
HOT
VOLTS PH HZ
MODELS
LEVELS
***
TY3-4X4E-H
240
3
60
2
TY3-4X5E-H
240
3
60
2
* INCLUDES INCANDESCENT LAMPS
** INCLUDES GROUND WIRE
*** TOTAL HEATED LEVELS = # ROWS OF SHELVES + BOTTOM WARMING SURFACE
OPTIONS/NOTES:
1) NOTE: CASE WIDTH INCLUDES END PANELS WITH OPTIONAL INTERIOR END PANELS
2) NOTE: CASES MUST BE GROUNDED
3) NOTE: LED LIGHTS ARE NOT AVAILABLE ON HOT CASES AT THIS TIME.
AMPS
AMPS
AMPS
WIRES
WATTS *
L1
L2
L3
**
4563
13.7
13.7
10.6
5
5764
17.5
17.5
13.0
5
AMPS
AMPS
AMPS
WIRES
WATTS *
L1
L2
L3
**
6069
15.8
15.8
12.2
5
7809
20.2
20.2
15.0
5
SELF-SERVICE HOT CASE
18
LEGEND
N/A -
NOT AVAILABLE
TBD -
TO BE DETERMINED
SBO -
SUPPLIED BY OTHERS
EXTERNAL END PANEL WIDTH KEY
END
TOTAL
# OF END
PNL
ADDED
PNLS
WIDTH
LENGTH
1
2.125
2.125
2
1.125
2.25
100814