Free Page - Magneti Marelli Smart Gas Operating Manual

Gas analyzer
Table of Contents

Advertisement

4.1 Free page

Press the ENTER key (↵) on the main menu to enter in "Free page".
After turning on the instrument, the warm up phase begins ("WARM UP"); it is
necessary to wait for the analysis cell to be properly warmed up before going
on with the test. During this phase the analyzer pump is off.
During the analyzer warm up, the display will show the wording "Please
wait " and a bar will indicate the operation progress.
The warm up average time is of 3-5 minutes depending on the environment
temperature.
At the end of the "WARM UP", the pump turns on, and the display shows the
message "Analyzer reset in progress, please wait".
After about 30 seconds the gas values will appear as shown below:
Insert the gas sampling probe in the exhaust pipe of a fuel vehicle to get the
gas analysis in real time.
Wait at least 30 seconds for the gas values stabilization,
then press ENTER (↵) and PRINT to print the results.
1161306-0
Example
CO= 0.00 %
CO2= 0.0 %
COc=
-.- %
λ= -.---
RPM= 0
T= --- C.
HC= 0
ppm
O2= 20.90 %
30