Specifications; Outdoor Unit Installation; Outdoor Unit Installation Instructions - Bosch Climate 5000 MS 18 Installation Manual

Inverter one-twin/one-three/one-four/one-five split-type air conditioner
Table of Contents

Advertisement

5

Specifications

Number of units that
Connected units
can be used together
Compressor stop/
Stop time
start frequency
Power source voltage
Voltage fluctuation
Voltage drop
during start
Interval unbalance
Table 3.
1 drive 2
Max. length for all
40
rooms
Max. length for
25
one indoor unit
Max. height
15
different between
indoor and
outdoor unit
Max. height
10
different between
indoor units
Table 4.
When installing multiple indoor units with a single outdoor unit, ensure
that the length of the refrigerant pipe and the drop height between
the indoor and outdoor units meets the requirements illustrated in the
following diagram:
Outdoor unit
Fig. 3.
Climate 5000 MS – 6720887246 (2018/04)
1-5 units
3 min or more
within ±10% of
rated voltage
within ±15% of
rated voltage
within ±3% of
rated voltage
Unit: m
1 drive 3
1 drive 4
1 drive 5
60
80
80
30
35
35
15
15
15
10
10
10
Indoor unit
Max. height difference
Indoor unit
Indoor unit
6

Outdoor Unit Installation

6.1

Outdoor Unit Installation Instructions

Step 1: Select installation location.
The outdoor unit should be installed in the location that meets the
following requirements:
f Place the outdoor unit as close to the indoor unit as possible.
f Ensure that there is enough room for installation and maintenance.
f The air inlet and outlet must not be obstructed or exposed to strong
wind.
f Ensure the location of the unit will not be subject to snowdrifts,
accumulation of leaves or other seasonal debris.
f The installation area must be dry and well ventilated.
f There must be enough room to install the connecting pipes and
cables and to access them for maintenance.
Strong wind
Fig. 4.
f The area must be free of combustible gases and chemicals.
f The pipe length between the outdoor and indoor unit may not exceed
the maximum allowable pipe length.
f If possible, DO NOT install the unit where it is exposed to direct
sunlight.
f If possible, make sure the unit is located far away from your
neighbours property so that the noise from the unit will not disturb
them.
f If the location is exposed to strong winds (for example: near
a seaside), the unit must be placed against the wall to shelter it from
the wind. If necessary, use an awning. (See Fig. 4 & 5)
f Install the indoor and outdoor units, cables and wires at least 1 metre
from televisions or radios to prevent static or image distortion.
Depending on the radio waves, a 1 metre distance may not be enough
to eliminate all interference.
Fig. 5.
Specifications
Strong wind
Strong wind
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Climate 5000 ms 27Climate 5000 ms 36Climate 5000 ms 42 ou-oue

Table of Contents