Product Information

1.3

Notices regarding these instructions

The figures are shown together at the end of these instructions. The text
contains references to the figures.
Depending on the model, the products may be different to those shown
in these instructions.
2
Product Information
2.1

Declaration of conformity

The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2

Technical data wired room controller

Power infeed
Permissible ambient temperature
Permissible relative humidity
Table 2 Technical data wired room controller
2.5

Information on refrigerant

This device contains fluorinated greenhouse gases as refrigerant. The
unit is hermetically sealed. The following information on the refrigerant
complies with the requirements of EU Regulation No. 517/2014 on
fluorinated greenhouse gases.
Product type
Rated cooling
output
[kW]
CL5000L 35 E
3.52
CL5000L 53 E
5.28
CL5000L 70 E
7.03
CL5000L 88 E
8.79
CL5000L 105 E
10.55
CL5000L 105 E-3
10.55
CL5000L 125 E
12.02
CL5000L 140 E-3
14.07
CL5000L 160 E-3
15.24
1) Total pipe length L in metres (if L > 5 m simple path from outdoor unit to indoor unit).
Table 5 F-Gas
38
DC 12V
−5 °C... 43 °C
40...90 %
Rated heating
Refrigerant
output
Type
[kW]
3.81
R32
5.57
R32
7.62
R32
9.38
R32
11.72
R32
11.72
R32
13.48
R32
16.12
R32
18.17
R32
2.3

Specifications of remote control

Power infeed
Signal range
Permissible ambient
temperature
Table 3 Specifications of remote control
2.4

Operating temperature range

Room temperature
Cooling
16 ... 32 °C
Heating
Dehumidifying
10... 32 °C
Table 4
The built-in protection device may prevent the appliance from operating
at temperatures outside the above range.
If the humidity is more than 80 %, condensation may form at the air
outlet. To prevent this, open the vertical ventilation flaps as wide as
possible (vertical relative to the ground) and set a high fan output.
Notice for the user: If your installer adds refrigerant, he enters the added
fill volume and the total amount of the refrigerant in the following table.
Global
CO
Initial
2
warming
equivalent
charge
potential
of initial
volume
(GWP)
charge
[kg Co
2
equ.]
675
0.49
675
0.78
675
1.01
675
1.35
675
1.62
675
1.62
675
1.89
675
1.96
675
2.03
Climate 5000 L • Climate 5000i U/L – 6721841496 (2021/10)
2 AAA batteries
8 m
16... 30 °C
Outside temperature
−15... 50 °C
0 ... 30 °C
−15... 24 °C
0... 50 °C
Additional fill
Total charge
volume for
volume during
pipe length
commissioning
1)
[kg]
L
[g/m]
0.72
12
1.15
12
1.5
12
2.0
24
2.4
24
2.4
24
2.8
24
2.9
24
3.0
24
[kg]

Advertisement