Filling The Hydraulic Fluid Reservoir; Preparing The Hydraulic Connections - TE Connectivity 69120-1 Customer's Manual

Heavy duty electric hydraulic pumps
Table of Contents

Advertisement

4.2. Filling the Hydraulic Fluid Reservoir

The pump is shipped without oil in the hydraulic fluid reservoir. The proper oil to be used is included with the
pump in a separate container. Fill the reservoir as follows:
DANGER
Always use proper eye protection and oil-resistant gloves when handling hydraulic fluid.
1. Make sure that the pump is NOT CONNECTED to the power supply.
2. Ensure that the entire area around the oil filler hole is clean. Any dirt or dust caught in the oil could
damage the polished surfaces and precision-fit components of the pump.
3. Remove the oil filler cap
4. Using a clean funnel with a clean filter, pour the oil into the reservoir. The proper level is 12.7 mm
[0.50 in.] from the top of the oil filler hole.
5.
NOTE
6.
Use only an approved brand of hydraulic oil (see Table 12).
Viscosity
Viscosity @
grade
38º C [100º F]
46
194-236 SSU
NOTE
To check the oil level and refill the reservoir after initial set-up, refer to section 6.2.

4.3. Preparing the Hydraulic Connections

1. Clean the areas around the hydraulic connection (oil pod) of the pump and the crimping heads.
2. Clean the areas around all of the hose ends and quick-disconnect couplers.
3. Remove the protector cap from the quick-disconnect coupler of each accessory.
4. Remove the protector cap from the hydraulic connection of the pump.
5. Inspect the threads and fittings for signs of wear or damage, and replace them as needed.
6. Optional: Seal the hydraulic connections by coating the threads of the quick-disconnect couplers with a
high-grade, non-hardening sealant.
7.
NOTE
A sealant is preferred, but PTFE tape can be used if only one layer of the tape is applied. If using the tape, apply it carefully to
prevent it from being pinched by the quick disconnect coupler and breaking off inside of the hose. Loose pieces of tape can
travel through the system and obstruct the flow of oil.
Rev G
Table 11: Hydraulic oil specifications
Pour point
Flash point
-29º C
181º C
[-20º F]
[357º F}
Table 12: Approved brands of hydraulic oil
Brand
Manufacturer
Hydro-Drive HP 200
EF Houghton and Co.
DTE 25
Mobil Oil Co.
Tellus 46
Shell Oil Co.
Rando Oil HD 46
Texaco Inc.
Specific
Neutral
Fire
gravity
number
221º C
28
0.1 max
[430º F}
409-1950
Condrason
carbon
0.05%
11 of 22