Table 1-2
Motor cable and fuse/MCB selection
Model
Input
Number
Phases
S100-01113
1
S100-01123
1
S100-01133
1
S100-03113
1
S100-03123
1
S100-03133
1
S100-01S13
1
S100-01213
3
S100-02S11
1
S100-01S23
1
S100-01223
3
S100-02S21
1
S100-01S33
1
S100-01233
3
S100-02S31
1
S100-01S43
1
S100-01243
3
S100-02S41
1
S100-01S53
1
S100-01253
3
S100-02S51
1
S100-01D63
1 / 3
S100-02S61
1
S100-01D73
1 / 3
S100-02S71
1
S100-03D13
1 / 3
S100-02413
3
S100-02423
3
S100-02433
3
S100-02443
3
S100-02453
3
S100-02463
3
S100-03413
3
S100-03423
3
* For UL installations, the circuit breaker must be listed under category control number DIVQ / DIVQ7, rated 600 Vac
with a short circuit rating > 10 kA. In other countries, circuit breakers compliant with EN IEC 60947-2 are
recommended, with > 10 kA short circuit breaking capacity.
IEC cable sizes assume Copper conductor, PVC insulation, installation method B2 and ambient temperature of 40 °C
(104 °F). For UL, cables must be rated for 75 °C (167 °F) operation and copper only. To fit a ferrule, 90 °C (194 °F)
rated cable with a reduced cross section is required for some drives.
The voltage rating of fuses and MCBs must be greater than or equal to the highest supply voltage of the
system.
Commander S100 Step by Step Guide
Fuses
Max Input
IEC
Current
Class
CC, J or
gG
A
A
7.19
10
8.49
10
10.4
12
14.8
16
20.01
25
28.54
32
3.3
6
1.95
4
3.3
6
3.84
6
2.28
4
3.84
6
4.74
6
2.84
4
4.74
6
8.01
10
4.74
6
8.01
10
9.51
12
5.69
8
9.51
12
15.28 / 12.60
16 / 16
15.28
16
18.41 / 14.25
20 / 16
18.41
20
26.10 / 19.74
32 / 25
1.92
4
2.5
4
3.04
4
4.54
6
5.59
8
8.18
10
13.18
16
16
20
MCB rating*
UL
Class
IEC
UL
T
A
A
A
110 V
10
10
15
15
10
15
15
12
15
20
16
25
30
25
25
40
32
40
230 V
6
6
15
6
6
15
6
6
15
6
6
15
6
6
15
6
6
15
6
6
15
6
6
15
6
6
15
10
10
15
6
6
15
10
10
15
15
12
15
10
8
15
15
12
15
20 / 15
20 / 16
20 / 15
20
20
20
25 / 20
25 / 16
20 / 20
25
25
20
35 / 25
32 / 25
30 / 25
400 V
6
6
15
6
6
15
6
6
15
6
6
15
10
8
15
15
16
15
20
16
15
25
20
20
Cables
IEC60364-5-52
UL61800-5-1
2
mm
Input
Output
Input
1.5
1.5
24
1.5
24
1.5
1.5
22
1.5
2.5
1.5
20
2.5
1.5
18
6
1.5
16
1.5
1.5
24
24
1.5
1.5
24
1.5
1.5
1.5
1.5
24
24
1.5
1.5
24
1.5
1.5
22
1.5
1.5
22
1.5
1.5
22
1.5
1.5
20
1.5
1.5
20
1.5
1.5
20
1.5
1.5
18
1.5
1.5
18
1.5
1.5
1.5
1.5
18
2.5
16
1.5
2.5
1.5
16
16
2.5
1.5
2.5
1.5
16
4
14
1.5
1.5
1.5
24
22
1.5
1.5
22
1.5
1.5
20
1.5
1.5
1.5
1.5
20
18
1.5
1.5
2.5
16
1.5
14
2.5
1.5
AWG
Output
24
24
22
20
18
16
24
24
24
24
24
24
22
22
22
20
20
20
18
18
18
16
16
14
14
14
24
22
22
20
20
18
16
14
4

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMMANDER S100 and is the answer not in the manual?

This manual is also suitable for:

Commander s100-01113Commander s100-01123Commander s100-01133Commander s100-03113Commander s100-03123Commander s100-03133 ... Show all

Table of Contents

Save PDF