Contents General ..............................4 Identification of the User Manual ......................4 Importance of the User Manual ......................... 4 Identification and specification, general warnings ................5 Identification and Specification ........................5 Safety instructions ..........................5 Secure installation of the machine ......................5 Safe operation of the machine ........................
General You have decided to purchase one of our Itensic training machines. We thank you for the trust you have shown us. The products of the Itensic machines are specially designed for the needs of the areas prevention and rehabilitation. All machine types are manufactured in Germany and meet the highest demands.
Identification and specification, general warnings Identification and Specification This User Manual is valid for the following machines: Itensic Abductor Item no. 10422800 Itensic Adductor Item no. 10422900 Safety instructions Secure installation of the machine Set the machine only in dry areas (< 65% rel. humidity) •...
Symbols: Type plate: In the type plate you can find the serial number, manufacturing date, address of the distributor. CE conformity marking Consult User Manual for use Manufacturer, address of the manufacturer Serial number, unique identification number Caution, refer to the accompanying documents, please ob- serve the safety-related instructions Dispose of the machine after decommissioning correctly Safe training...
Indicators and contra-indicators 3.5.1 Indicators Abductor: • Chronic degenerative diseases of the lower limb (e.g., hip or knee joint arthrosis, impingement syn- drome) • To mention Hip operations or lower limb operations (e.g., hip or knee endoprostheses, mucus removal, osteotomy switching) •...
Angina pectoris (paroxysmal pain in the chest) Maximum pulse > 220 - age [s Nausea Circulation problems Malaise Rapidly decreasing heart rate Rapidly dropping / rising blood pressure Known electrolyte disorder Use and Area of Application The system is designed to be used in the following fields of application: •...
Use the maintenance plan given on delivery to maintain the machines. Note! If you do however fine some unexpected damage stop the training immediately. If there is a problem, which you cannot easily solve then contact the proxomed Service. The authorised ®...
Exercise instructions The correct positioning of the patient in the starting position contributes greatly to the quality and effectiveness of the exercise. The machines are used to train the exercises in a sitting position. The back, in particular the lumbar spinal col- umn, is to be actively stabilised during the exercise execution by an upright sitting position.
Abductor Correct usage The machine is designed for the functional training of the hip abducting muscles in the open system. With this machine the hip abduction is trained in a functional moving manner. The load is applied both concentrically and eccentrically.
Adductor Correct usage The machine is designed for the functional training of the hip abducting muscles in the open system. With this machine the hip adduction is trained in a functional moving manner. The load is applied both concentrically and eccentrically.
Load dosing The load on the training machines is changed by altering the inclination adjustment as well as the possibility of adding additional weights to the machine. The steeper the machine is set, the more resistance must be over- come by the working musculature. The acting weight is determined by the following formula: ...
Page 14
56,5 47,6 38,4 29,6 19,9 10,7 60,0 50,5 40,8 31,4 21,1 11,3 63,5 53,5 43,2 33,2 22,3 11,9 67,1 56,4 45,5 35,1 23,6 12,6 Zur Berechnung der Zwischenstufen des Körperge- wichts oder der Verwendung von Zusatzgewichten, erhöht sich pro Kilogramm der zu überwindende Widerstand um die unten angegebe- nen Werte.
The client should return the defective parts to us within 48 hours. Otherwise, the delivered spare part will be in- voiced. If the cause is not within the warranty / guarantee guidelines, then proxomed reserves the right to invoice all re- pair costs.