6.
TROUBLESHOOTING
C
a
u
No spray on injector or a little quantity
No start
of the
Speed control rod not at "RUN" position
engine
Check lube oil lever
Dirty on the nozzle
No electricity in battery
Not turn on the switch
No output
Worse contact of the socket
of generator
Not reach rated speed of the engine
Not reach rated speed of the engine
Voltage
too low
(1) lack of the fuel
Automatic
(2) lack of lube oil
stop after
a certain
(3) voltage too low/too high
time of
(4) frequency too low/too high
operation
s
e
s
Insufficient fuel
Air in fuel circuit
Check AVR
(5) over-current
R
e
m
e
d
e i
s
Fill in the fuel
Purge air in fuel circuit
Repair and adjust the injector
Set control rod to "RUN" position
The level between upper mark "H"
and lower mark "L"
Clean the nozzle
Charge or change the battery
Turn to "CLOSE" position
Adjust the socket
According the stipulation
Set speed control rod to operation position.
Adjust the resistance clockwise
Repair according to relative
alarming of control panel